持续充盈的颈内动脉囊状动脉瘤经Pipeline栓塞装置血流导向治疗后的长期随访中未见延迟破裂的病例系列
本研究基于974例血流导向治疗病例数据库,筛选出94例颈内动脉床突段、眼段及交通段囊状动脉瘤,在Pipeline栓塞装置(PED)治疗后1年导管造影仍持续充盈。平均随访4.9年,91.5%的动脉瘤未行再治疗,无延迟性蛛网膜下腔出血病例。结论提示对于PED术后至少最初几年内持续充盈的动脉瘤,观察可能是合适的。
要点
- 94例PED术后1年持续充盈的颈内动脉囊状动脉瘤中,平均随访4.9年无延迟破裂。
- 91.5%的持续充盈动脉瘤未行再治疗,随访期间无延迟性蛛网膜下腔出血。
- 作者认为,PED术后至少最初几年内对持续充盈动脉瘤进行观察可能是合适的。
核心结论
- 在PED治疗后1年仍持续充盈的颈内动脉囊状动脉瘤中,长期随访未见延迟破裂病例。
- 这些数据提示,对于PED术后至少最初几年内持续充盈的动脉瘤,观察可能是合适的。
研究设计与样本
- 研究为本机构974例血流导向治疗病例数据库的病例系列分析。
- 纳入标准为颈内动脉床突段、眼段及交通段囊状动脉瘤,经Pipeline栓塞装置(PED,美敦力)治疗,且1年导管造影显示动脉瘤持续充盈。
- 共识别94例持续充盈动脉瘤,要求临床随访至少2年。
主要发现
- 未治疗动脉瘤平均大小为5.6 mm。
- 分支血管起源情况:55%的病例分支血管单独起源,10.6%起源于瘤体,34%起源于瘤颈。
- 1年时18%的动脉瘤充盈程度>95%,61%的动脉瘤充盈程度为原始大小的5%至95%。
- 平均随访时间为4.9年,其中41例随访超过5年。
- 91.5%的动脉瘤未行再治疗,无延迟性蛛网膜下腔出血病例。
临床怎么用
- 作者认为,对于PED术后至少最初几年内持续充盈的颈内动脉囊状动脉瘤,观察可能是合适的。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Flow diversion of intracranial aneurysms results in high occlusion rates. However, 10% to 20% remain persistently filling at 1 year. Often, these are retreated, but benefits of retreatment are not well established. A better understanding of the long-term rupture risk of persistently filling aneurysms after flow diversion is needed. METHODS: Our institutional database of 974 flow diversion cases was queried for persistently filling saccular aneurysms of the clinoidal, ophthalmic, and communicating segments of the internal carotid artery treated with the pipeline embolization device (PED, Medtronic). Persistent filling was defined as continued flow into the aneurysm on 1 year catheter angiogram. The clinical record was queried for retreatments and delayed ruptures. Clinical follow-up was required for at least 2 years. RESULTS: Ninety-four persistent aneurysms were identified. The average untreated aneurysm size was 5.6 mm. A branch vessel originated separately in 55% of cases from the body of the aneurysm in 10.6% of cases and from the neck in 34% of cases. Eighteen percent of aneurysms demonstrated >95% filling at 1 year, and 61% were filling 5% to 95% of their original size. The mean follow-up time was 4.9 years, including 41 cases with >5 years. No retreatment was undertaken in 91.5% of aneurysms. There were no cases of delayed subarachnoid hemorrhage. CONCLUSION: Among saccular internal carotid artery aneurysms treated with PED that demonstrated persistent aneurysm filling at 1 year, there were no instances of delayed rupture on long-term follow-up. These data suggest that observation may be appropriate for continued aneurysm filling at least in the first several years after PED placement.
引用
- Lee RP, Bhimreddy M, Kim J, et al. No Delayed Ruptures on Long-Term Follow-Up of a Case Series of Persistently Filling Saccular Internal Carotid Artery Aneurysms After Flow Diversion With the Pipeline Embolization Device. Neurosurgery. 2023. PMID: 37255292. doi:10.1227/neu.0000000000002521
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。