显微外科夹闭作为WEB装置治疗既往破裂动脉瘤的再治疗策略:单中心病例系列
该单中心回顾性病例系列纳入2019至2021年本院收治的5例破裂动脉瘤患者,均先接受WEB装置治疗,后因动脉瘤残留或复发改行显微外科夹闭。所有动脉瘤夹闭可行且安全,5例中4例实现完全闭塞。作者结论认为,对经过筛选的既往破裂WEB治疗动脉瘤患者,显微外科夹闭是可行、安全且有效的再治疗方法。
要点
- 5例破裂动脉瘤先以WEB装置治疗,后因残留或复发改行显微外科夹闭。
- 除1例基底动脉尖动脉瘤外,其余动脉瘤均位于前交通动脉复合体。
- 所有动脉瘤均为宽颈,平均瘤顶颈比为1.5。
核心结论
- 对经过筛选的既往破裂WEB治疗动脉瘤患者,显微外科夹闭是可行、安全且有效的再治疗方法。
研究设计与样本
- 单中心回顾性研究,纳入2019至2021年本院所有因破裂动脉瘤接受WEB治疗的患者,随后识别其中因目标动脉瘤残留或复发而改行显微外科夹闭的患者。
- 共纳入5例破裂动脉瘤患者,先接受WEB治疗,后改行显微外科夹闭。
主要发现
- 除1例基底动脉尖动脉瘤外,其余动脉瘤均位于前交通动脉复合体。
- 所有动脉瘤均为宽颈,平均瘤顶颈比为1.5。
- 夹闭在所有动脉瘤中可行且安全,5例中4例实现完全闭塞。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Since its approval by the US Food and Drug Administration (FDA) in 2018, the flow disruptor Woven EndoBridge (WEB) device has become increasingly popular for the endovascular treatment of unruptured and ruptured cerebral aneurysms. However, the occlusion rates seem rather low and the retreatment rates rather high compared to other treatment methods. For initially ruptured aneurysms, a retreatment rate of 13 % has been reported. A variety of retreatment strategies has been proposed; however, there is a paucity of data concerning microsurgical clipping of WEB-pretreated aneurysms, especially previously ruptured ones. Thus, we present a single-center series of five ruptured aneurysms treated with the WEB device and retreated with microsurgical clipping. METHODS: A retrospective study including all patients presenting with a ruptured aneurysm undergoing WEB treatment at our institution between 2019 and 2021 was performed. Subsequently, all patients with an aneurysm remnant or recurrence of the target aneurysm retreated with microsurgical clipping were identified. RESULTS: Overall, five patients with a ruptured aneurysm treated with WEB and retreated with microsurgical clipping were included. Besides one basilar apex aneurysm, all aneurysms were located at the anterior communicating artery (AComA) complex. All aneurysms were wide-necked with a mean dome-to-neck ratio of 1.5. Clipping was feasible and safe in all aneurysms, and complete occlusion was achieved in 4 of 5 aneurysms. CONCLUSIONS: Microsurgical clipping for initially ruptured WEB-treated aneurysms is a feasible, safe, and effective treatment method in well-selected patients.
引用
- Kranawetter B, Hernández S, Mielke D, et al. Microsurgical clipping as a retreatment strategy for previously ruptured aneurysms treated with the Woven EndoBridge (WEB) device: a mono-institutional case series. Acta Neurochir (Wien). 2023. PMID: 37178247. doi:10.1007/s00701-023-05596-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。