表观扩散系数(ADC)图能否替代弥散张量成像(DTI)图预测脑膜瘤对伽玛刀放射外科的体积反应?
回顾性分析70例WHO I级脑膜瘤患者伽玛刀放射外科治疗前后的DWI和DTI图像,比较瘤内ADC与DTI参数的预测价值。平均随访52.7个月,69/70例肿瘤控制,平均体积缩小34.9%。初始FA值与末次随访肿瘤体积变化相关性最高(CC=-0.607),ADC各值相关性均较低,但除第一次随访时测得的ADC外均达统计学显著。
要点
- 初始FA值与末次随访肿瘤体积变化相关性最高(CC=-0.607)。
- ADC各值与肿瘤体积变化相关性均较低,但多数达统计学显著。
- ADC图与肿瘤体积反应显著相关,但预测效果不及DTI参数。
核心结论
- 首次比较脑膜瘤伽玛刀放射外科前及第一次随访时ADC图与同期采集的DTI参数图的预后价值,ADC图测量值与脑膜瘤体积反应显著相关,但相关性不如DTI参数有效。
研究设计与样本
- 回顾性分析70例接受伽玛刀放射外科治疗的WHO I级脑膜瘤患者的MR图像,采集治疗前后DWI和DTI序列并计算减影以评估辐射诱导的参数值变化。
主要发现
- 平均随访52.7个月后,70例脑膜瘤中69例控制,平均体积缩小34.9%。
- 初始检查的FA值与末次随访肿瘤体积变化相关性最高(CC=-0.607),其次为第一次与第二次随访FA值之差(CC=-0.404)和第一次纵向弥散率(LD)值(CC=-0.375)。
- 所有ADC值的相关系数均较低,但除第一次随访时测得的ADC外,所有相关性均达统计学显著。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Noninvasive methods are desired to predict the treatment response to Stereotactic Radiosurgery (SRS) to improve individual tumor management. In a previous study, we demonstrated that Diffusion Tensor Imaging (DTI)-derived parameter maps significantly correlate to SRS response. This study aimed to analyze and compare the predictive value of intratumoral ADC and DTI parameters in patients with meningiomas undergoing radiosurgery. METHODS: MR images of 70 patients treated with Gamma Knife SRS for WHO grade I meningiomas were retrospectively reviewed. MR acquisition included pre- and post-treatment DWI and DTI sequences, and subtractions were calculated to assess for radiation-induced changes in the parameter values. RESULTS: After a mean follow-up period (FUP) of 52.7 months, 69 of 70 meningiomas were controlled, with a mean volume reduction of 34.9%. Whereas fractional anisotropy (FA) values of the initial exam showed the highest correlation to tumor volume change at the last FU (CC = - 0.607), followed by the differences between first and second FU values of FA (CC = - 0.404) and the first longitudinal diffusivity (LD) value (CC = - 0.375), the correlation coefficients of all ADC values were comparably low. Nevertheless, all these correlations, except for ADC measured at the first follow-up, reached significance. CONCLUSION: For the first time, the prognostic value of ADC maps measured in meningiomas before and at first follow-up after Gamma Knife SRS, was compared to simultaneously acquired DTI parameter maps. Quantities assessed from ADC maps present significant correlations to the volumetric meningioma response but are less effective than correlations with DTI parameters.
引用
- Speckter H, Palque-Santos S, Mota-Gonzalez R, et al. Can Apparent Diffusion Coefficient (ADC) maps replace Diffusion Tensor Imaging (DTI) maps to predict the volumetric response of meningiomas to Gamma Knife Radiosurgery? J Neurooncol. 2023. PMID: 36745271. doi:10.1007/s11060-023-04243-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。