成人脑中线弥漫性中线胶质瘤H3 K27变异型、H3 K27野生型高级别胶质瘤及原发性中枢神经系统淋巴瘤预测机器学习算法的开发与验证
本研究回顾性纳入33例DMG-A、35例DMG-W和35例中线PCNSL患者,提取对比增强T1加权MR图像的放射组学特征并结合临床特征,通过机器学习建立预测模型,并在外部机构纳入10例DMG-A、10例DMG-W和12例PCNSL患者进行验证。基于支持向量机的整合模型在测试队列中准确率达0.903,对三种实体具有高判别准确率。
要点
- 整合临床与放射组学特征的支持向量机模型在测试队列中准确率为0.903。
- 年龄、2个放射组学特征和3个常规MRI特征是整合模型中最重要的6个特征。
- 外部验证队列纳入10例DMG-A、10例DMG-W和12例PCNSL患者。
核心结论
- 通过机器学习建立的整合预测模型对成人DMG-A、DMG-W和中线PCNSL具有高判别准确率。
研究设计与样本
- 回顾性纳入33例DMG-A、35例DMG-W和35例中线PCNSL患者,从对比增强T1加权MR图像提取放射组学特征,由两名放射科医生评估肿瘤常规MRI特征,患者年龄、肿瘤体积和常规MRI特征作为临床特征。
- 数据集按70%训练和30%测试随机分层,通过机器学习建立基于临床特征、放射组学特征及两者整合的预测模型。
- 从另一机构纳入10例DMG-A、10例DMG-W和12例PCNSL患者对建立的模型进行验证。
主要发现
- 基于临床特征、放射组学特征及两者整合的支持向量机算法模型在训练、测试和验证队列中准确率最优,测试队列准确率分别为0.871、0.892和0.903。
- 年龄、2个放射组学特征和3个常规MRI特征是建立的整合模型中最重要的6个特征。
关键数值与推荐
- 测试队列中临床特征模型准确率为0.871,放射组学特征模型为0.892,整合模型为0.903。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Preoperative diagnosis of diffuse midline glioma, H3 K27-altered (DMG-A) and midline high-grade glioma without H3 K27 alteration (DMG-W), as well as midline primary CNS lymphoma (PCNSL) in adults, is challenging but crucial. The aim of this study was to develop a model for predicting these three entities using machine learning (ML) algorithms. METHODS: Thirty-three patients with DMG-A, 35 with DMG-W, and 35 with midline PCNSL were retrospectively enrolled in the study. Radiomics features were extracted from contrast-enhanced T1-weighted MR images. Two radiologists evaluated the conventional MRI features of the tumors, such as shape. Patient age, tumor volume, and conventional MRI features were considered clinical features. The data set was randomly stratified into 70% training and 30% testing cohorts. Predictive models based on the clinical features, radiomics features, and integration of clinical and radiomics features were established through ML. The performances of the models were evaluated by calculating the area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity. Subsequently, 10 patients with DMG-A, 10 with DMG-W, and 12 with PCNSL were enrolled from another institution to validate the established models. RESULTS: The predictive models based on clinical features, radiomics features, and the integration of clinical and radiomics features through the support vector machine algorithm had the optimal accuracies in the training, testing, and validation cohorts, and the accuracies in the testing cohort were 0.871, 0.892, and 0.903, respectively. Age, 2 radiomics features, and 3 conventional MRI features were the 6 most significant features in the established integrated model. CONCLUSIONS: The integrated prediction model established by ML provides high discriminatory accuracy for predicting DMG-A, DMG-W, and midline PCNSL in adults.
引用
- Lv K, Chen H, Cao X, et al. Development and validation of a machine learning algorithm for predicting diffuse midline glioma, H3 K27-altered, H3 K27 wild-type high-grade glioma, and primary CNS lymphoma of the brain midline in adults. J Neurosurg. 2022. PMID: 36681946. doi:10.3171/2022.11.JNS221544
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。