使用5-ALA荧光头灯与放大镜组合切除的高级别胶质瘤样本的组织学研究
本研究对14例患者使用头灯/放大镜装置切除的术中样本按荧光强度分为粉色、模糊和阴性,并与组织学及术后MRI切除程度对比。荧光程度与组织学结果显著相关(X2=42.57,p<0.00001),粉色对胶质母细胞瘤或高级别浸润性胶质瘤的阳性预测值为88.4%(38/43),术中全切除对术后MRI全切除的阳性预测值为100%。
要点
- 粉色、模糊和阴性标本的细胞密度差异显著(ANOVA,p<0.00001)。
- 粉色荧光对胶质母细胞瘤或高级别浸润性胶质瘤的阳性预测值为88.4%(38/43)。
- 术中全切除对术后MRI全切除的阳性预测值为100%。
核心结论
- 头灯/放大镜装置可提供关于组织学、细胞密度和坏死的信息,其对肿瘤的阳性预测值与手术显微镜相似。
- 安全完全切除荧光组织的阳性预测值为100%,应作为手术目标。
研究设计与样本
- 研究纳入14例患者,使用头灯/放大镜装置切除术中样本,按荧光程度标记为粉色、模糊或阴性,并进行组织学评估。
主要发现
- 粉色、模糊和阴性标本的细胞密度差异显著(ANOVA,p<0.00001)。
- 粉色对胶质母细胞瘤或高级别浸润性胶质瘤的阳性预测值为88.4%(38/43)。
- 阴性对浸润性胶质瘤或非诊断性标本的阴性预测值为74.4%(29/39)。
- 荧光程度判定与组织学结果的关系显著(X2(6个自由度,N=101)=42.57,p<0.00001)。
- 术中全切除对术后MRI全切除的阳性预测值为100%,术中次全切除对术后MRI次全切除的阴性预测值为60%。
临床怎么用
- 作者认为安全完全切除荧光组织的阳性预测值为100%,应作为手术目标。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: 5-Aminolevulinic acid (5-ALA) fluorescence-guided resection of high-grade gliomas (HGG) increases the extent of resection (EOR) and progression-free survival. The headlamp/loupe combination has been introduced as a method of performing fluorescent-guided surgery. This study aims to understand the correlation between fluorescent intensity and histology and between residual fluorescence and radiographic EOR utilizing the headlamp/loupe device. METHODS: Intraoperative samples resected using the headlamp/loupe device from 14 patients were labeled as PINK, VAGUE, or NEGATIVE depending on the degree of fluorescence. Histological assessment of microvascular proliferation, necrosis, and cell density was performed, and samples were classified as histologically consistent with glioblastoma (GBM), high-grade infiltrating glioma (HGIG), IG, or non-diagnostic (NDX). The presence of intraoperative residual fluorescence was compared to EOR on post-operative MRI. RESULTS: There was a significant difference in cell density comparing PINK, VAGUE, and NEGATIVE specimens (ANOVA, p < 0.00001). The PPV of PINK for GBM or HGIG was 88.4% (38/43). The NPV of NEGATIVE for IG or NDX was 74.4% (29/39). The relationship between the degree of fluorescence determination and histological results was significant (X2 (6 degrees of freedom, N = 101) = 42.57, p < 0.00001). The PPV of intraoperative GTR for post-operative GTR on MRI was 100%, while the NPV of intraoperative STR for post-operative STR on MRI was 60%. CONCLUSION: The headlamp/loupe device provides information about histology, cell density, and necrosis with similar PPV for tumor to the operative microscope. Safe complete resection of florescence has a PPV of 100% for radiographic GTR and should be the goal of surgery.
引用
- Giantini-Larsen AM, Kharas N, Pisapia D, et al. Histology of high-grade glioma samples resected using 5-ALA fluorescent headlight and loupe combination. Acta Neurochir (Wien). 2023. PMID: 36656388. doi:10.1007/s00701-023-05496-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。