基于时间依赖扩散MRI微观结构映射的儿童胶质瘤组织学与分子分型
这项前瞻性研究纳入69例儿童胶质瘤患者(年龄6.14±3.25岁),采用时间依赖扩散MRI(td-dMRI)微观结构映射技术量化肿瘤细胞特性。结果显示细胞密度指数在组织学分级中AUC达0.911,细胞直径在H3K27变异型胶质瘤分子分型中AUC达0.918,td-dMRI估计的细胞内分数与组织学金标准相关性r=0.7。
要点
- 细胞密度指数鉴别儿童胶质瘤低级别与高级别的AUC为0.911,优于ADC(0.906)、T1(0.885)和T2(0.886)。
- 在39例中线胶质瘤患者中,细胞直径判别H3K27变异型的AUC为0.918,联合细胞外弥散系数后AUC提升至0.929。
- td-dMRI估计的细胞内分数(fin)与组织学验证结果相关性r=0.7。
核心结论
- 基于td-dMRI的微观结构特性在诊断儿童胶质瘤方面优于常规MRI测量,且不同微观结构特征在组织学与分子分型中表现出互补优势。
研究设计与样本
- 前瞻性研究纳入69例儿童胶质瘤患者,年龄6.14±3.25岁,在3T扫描仪上接受脉冲梯度和振荡梯度扩散序列的td-dMRI检查。
- 将不同扩散时间下采集的dMRI数据拟合至双室微观结构模型,获得细胞内分数(fin)、细胞直径、细胞密度等参数,同时获取ADC及T1、T2弛豫时间。
- 采用H&E染色组织学验证估计的微观结构特性。
主要发现
- 在儿童胶质瘤低级别与高级别的组织学分类中,细胞密度指数在所有标志物中AUC最高,为0.911;ADC、T1和T2的AUC分别为0.906、0.885和0.886。
- 在39例中线胶质瘤患者的H3K27变异型分子分类中,细胞直径判别力最高,AUC为0.918;细胞直径联合细胞外弥散系数使AUC进一步提升至0.929。
- td-dMRI估计的细胞内分数(fin)与组织学金标准相关性良好,r=0.7。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Gliomas are the most common type of central nervous system tumors in children, and the combination of histological and molecular classification is essential for prognosis and treatment. Here, we proposed a newly developed microstructural mapping technique based on diffusion-time-dependent diffusion MRI td-dMRI theory to quantify tumor cell properties and tested these microstructural markers in identifying histological grade and molecular alteration of H3K27. METHODS: This prospective study included 69 pediatric glioma patients aged 6.14 ± 3.25 years old, who underwent td-dMRI with pulsed and oscillating gradient diffusion sequences on a 3T scanner. dMRI data acquired at varying tds were fitted into a 2-compartment microstructural model to obtain intracellular fraction (fin), cell diameter, cellularity, etc. Apparent diffusivity coefficient (ADC) and T1 and T2 relaxation times were also obtained. H&E stained histology was used to validate the estimated microstructural properties. RESULTS: For histological classification of low- and high-grade pediatric gliomas, the cellularity index achieved the highest area under the receiver-operating-curve (AUC) of 0.911 among all markers, while ADC, T1, and T2 showed AUCs of 0.906, 0.885, and 0.886. For molecular classification of H3K27-altered glioma in 39 midline glioma patients, cell diameter showed the highest discriminant power with an AUC of 0.918, and the combination of cell diameter and extracellular diffusivity further improved AUC to 0.929. The td-dMRI estimated fin correlated well with the histological ground truth with r = 0.7. CONCLUSIONS: The td-dMRI-based microstructural properties outperformed routine MRI measurements in diagnosing pediatric gliomas, and the different microstructural features showed complementary strength in histological and molecular classifications.
引用
- Zhang H, Liu K, Ba R, et al. Histological and molecular classifications of pediatric glioma with time-dependent diffusion MRI-based microstructural mapping. Neuro Oncol. 2023. PMID: 36617263. doi:10.1093/neuonc/noad003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。