血液黏度模型与边界条件对计算流体力学计算脑动脉瘤血流动力学参数的影响
研究以塞流与Womersley流为入口边界条件、零压与搏动压为出口边界条件,分析不同黏度假设随流量的差异,并用Tupin等的粒子图像测速实验数据验证CFD流程。结果显示入口段足够长时入口与出口边界条件不影响CFD结果,牛顿与非牛顿流体的血流动力学参数差异随流量增大而减小,在患者特异性脑动脉瘤模型中评估到相似趋势。
要点
- 入口段充分保证时,入口与出口边界条件不影响CFD结果。
- 牛顿与非牛顿流体的血流动力学参数差异随流量增大而减小。
- 上述建议用于患者特异性脑动脉瘤模型时评估到相似趋势。
核心结论
- 结果可能有助于不同研究组开展标准化的CFD分析。
研究设计与样本
- 以塞流与Womersley流为入口边界条件、零压与搏动压为出口边界条件,分析不同黏度假设随流量的差异,并用Tupin等的粒子图像测速实验数据验证CFD流程。
主要发现
- 入口段足够长时,入口与出口边界条件不影响CFD结果。
- 牛顿与非牛顿流体之间的血流动力学参数差异随流量增大而减小。
- 上述建议用于患者特异性脑动脉瘤模型时评估到相似趋势。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Computational fluid dynamics (CFD) is widely used to calculate hemodynamic parameters that are known to influence cerebral aneurysms. However, the boundary conditions for CFD are chosen without any specific criteria. Our objective is to establish the recommendations for setting the analysis conditions for CFD analysis of the cerebral aneurysm. METHOD: The plug and the Womersley flow were the inlet boundary conditions, and zero and pulsatile pressures were the outlet boundary conditions. In addition, the difference in the assumption of viscosity was analyzed with respect to the flow rate. The CFD process used in our research was validated using particle image velocimetry experiment data from Tupin et al.'s work to ensure the accuracy of the simulations. RESULTS: It was confirmed that if the entrance length was sufficiently secured, the inlet and outlet boundary conditions did not affect the CFD results. In addition, it was observed that the difference in the hemodynamic parameter between Newtonian and non-Newtonian fluid decreased as the flow rate increased. Furthermore, it was confirmed that similar tendencies were evaluated when these recommendations were utilized in the patient-specific cerebral aneurysm models. CONCLUSIONS: These results may help conduct standardized CFD analyses regardless of the research group.
引用
- Yang H, Hong I, Kim YB, et al. Influence of blood viscosity models and boundary conditions on the computation of hemodynamic parameters in cerebral aneurysms using computational fluid dynamics. Acta Neurochir (Wien). 2023. PMID: 36624234. doi:10.1007/s00701-022-05467-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。