创伤性脑损伤患者颅内压脉冲波形分析:CENTER-TBI研究
该研究纳入CENTER-TBI高分辨率子研究中的184例创伤性脑损伤患者,采用频谱方法分析颅内压脉冲波形参数(AMP、HFC、HHC)及形态学分类指标PSI。结果显示AMP、HFC和PSI在死亡患者中显著高于存活患者,且在低颅内压(<15 mm Hg)患者中预后不良者高于预后良好者;HHC可能作为颅内高压的早期预警信号。
要点
- AMP、HFC和PSI在死亡患者中显著高于存活患者(p<0.001、p=0.003、p<0.001)。
- 低颅内压(<15 mm Hg)患者中,预后不良者的AMP、PSI和HFC均高于预后良好者(均p<0.001)。
- HHC在颅内压超过25 mm Hg时显著下降,可能作为颅内高压的早期预警信号。
核心结论
- HFC、AMP和PSI可作为死亡预测指标,HHC可能作为颅内高压的早期预警信号。
- 在低颅内压的创伤性脑损伤患者中,HFC、AMP和PSI升高与预后不良相关。
研究设计与样本
- 研究纳入来自欧洲协作神经创伤有效性研究(CENTER-TBI)高分辨率子研究的184例创伤性脑损伤患者,采用频谱方法分析颅内压脉冲波形,计算AMP、HFC、HHC和PSI。
主要发现
- AMP和PSI随平均颅内压线性增加。
- HFC随颅内压升高而成比例增加,直至上限拐点(平均颅内压31 mm Hg)。
- HHC随颅内压升高轻度增加,当颅内压超过25 mm Hg时显著下降。
- 死亡患者的AMP(p<0.001)、HFC(p=0.003)和PSI(p<0.001)均显著高于存活患者。
- 在低颅内压(<15 mm Hg)患者中,预后不良者的AMP、PSI和HFC均高于预后良好者(均p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Intracranial pressure (ICP) pulse waveform analysis may provide valuable information about cerebrospinal pressure-volume compensation in patients with traumatic brain injury (TBI). The authors applied spectral methods to analyze ICP waveforms in terms of the pulse amplitude of ICP (AMP), high frequency centroid (HFC), and higher harmonics centroid (HHC) and also used a morphological classification approach to assess changes in the shape of ICP pulse waveforms using the pulse shape index (PSI). METHODS: The authors included 184 patients from the Collaborative European NeuroTrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI) High-Resolution Sub-Study in the analysis. HFC was calculated as the average power-weighted frequency within the 4- to 15-Hz frequency range of the ICP power density spectrum. HHC was defined as the center of mass of the ICP pulse waveform harmonics from the 2nd to the 10th. PSI was defined as the weighted sum of artificial intelligence-based ICP pulse class numbers from 1 (normal pulse waveform) to 4 (pathological waveform). RESULTS: AMP and PSI increased linearly with mean ICP. HFC increased proportionally to ICP until the upper breakpoint (average ICP of 31 mm Hg), whereas HHC slightly increased with ICP and then decreased significantly when ICP exceeded 25 mm Hg. AMP (p < 0.001), HFC (p = 0.003), and PSI (p < 0.001) were significantly greater in patients who died than in patients who survived. Among those patients with low ICP (< 15 mm Hg), AMP, PSI, and HFC were greater in those with poor outcome than in those with good outcome (all p < 0.001). CONCLUSIONS: Whereas HFC, AMP, and PSI could be used as predictors of mortality, HHC may potentially serve as an early warning sign of intracranial hypertension. Elevated HFC, AMP, and PSI were associated with poor outcome in TBI patients with low ICP.
引用
- Uryga A, Ziółkowski A, Kazimierska A, et al. Analysis of intracranial pressure pulse waveform in traumatic brain injury patients: a CENTER-TBI study. J Neurosurg. 2022. PMID: 36681948. doi:10.3171/2022.10.JNS221523
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。