立体定向框架专用3D打印附件在脑深部电刺激手术中的临床应用
本研究设计了一种可安装于Cosman-Roberts-Wells立体定向框架的3D打印手术导板,用于辅助钻孔以引入微电极。在11例帕金森病双侧脑深部电刺激微电极置入患者中,术中应用该导板显示微电极置入精度高,平均偏差1.18 mm(范围0-2.7 mm),未发生术中并发症。
要点
- 3D打印导板可安装于Cosman-Roberts-Wells立体定向框架,辅助钻孔定位。
- 11例帕金森病双侧脑深部电刺激患者中,微电极置入平均偏差1.18 mm(范围0-2.7 mm)。
- 术中未发生并发症,导板减少了手术时间、多次轨迹需求及潜在神经并发症风险。
核心结论
- 该概念验证研究显示,可完全定制且快速生产的3D打印手术附件有助于改善现有手术实践。
- 导板减少了手术时间、多次轨迹的需求以及潜在毁灭性神经并发症的风险。
- 3D打印设备可作为手术附件,用于优化脑深部电刺激手术的安全性和有效性。
研究设计与样本
- 研究设计并展示了可安装于Cosman-Roberts-Wells立体定向框架的3D打印手术导板的临床使用。
- 在11例接受双侧脑深部电刺激微电极置入的帕金森病患者中术中使用了该导板。
主要发现
- 11例患者中微电极置入精度高,平均偏差1.18 mm(范围0-2.7 mm),偏离预定轨迹。
- 术中未遇到并发症。
临床怎么用
- 作者认为,3D打印设备可作为手术附件,用于优化脑深部电刺激手术的安全性和有效性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mispositioning of microelectrodes during deep brain stimulation surgery can incur serious complications for patients. Current practice of creating a burr hole for introduction of the microelectrode is done freehand and can cause trajectory misalignment. We aimed to create a sterilizable surgical adjunct to minimize error from burr hole placement. METHODS: We designed and demonstrated clinical use of a 3D-printed surgical jig that can be mounted to the current Cosman-Roberts-Wells stereotactic frame. The jig allowed accurate placement of the perforating burr for creation of the burr hole. RESULTS: Intraoperative usage of the jig in 11 patients who underwent bilateral deep brain stimulation microelectrode placement for Parkinson disease demonstrated high accuracy of microelectrode placement, with an average 1.18 mm deviation (range, 0-2.7 mm) from intended trajectories. No intraoperative complications were encountered. CONCLUSIONS: This proof-of-concept study highlights the utility of 3D-printed surgical adjuncts that are fully customizable and rapidly produced to improve current surgical practice. The jig reduced surgery duration, need for multiple trajectories, and risk of potentially devastating neurological complications. As demonstrated, 3D-printed devices are useful as surgical adjuncts to optimize safety and efficacy in deep brain stimulation surgeries.
引用
- Ang J, Zhang JJY, Yam M, et al. Clinical Application of a Stereotactic Frame-Specific 3D-Printed Attachment for Deep Brain Stimulation Surgery. World Neurosurg. 2022. PMID: 36455844. doi:10.1016/j.wneu.2022.11.121
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。