神经调控术中伤口并发症的挽救性处理应用
回顾性分析8年间40例神经调控装置相关伤口并发症患者,29例接受冲洗、10例部分移除、1例移除后更换。冲洗成功率15/29(51.7%),部分移除成功率2/10(20%),移除后更换失败(0/1)。冲洗成功率有高于部分移除的趋势(P=0.08),部分装置移除及手术部位存在脓性分泌物者冲洗失败率较高。
要点
- 冲洗成功15/29例(51.7%),部分移除成功2/10例(20%),移除后更换失败(0/1)。
- 冲洗成功率有高于部分移除的趋势(P=0.08)。
- 部分装置移除及手术部位存在脓性分泌物者冲洗失败率较高。
核心结论
- 部分装置移除及手术部位存在脓性分泌物者冲洗失败率较高。
- 需进一步研究以确定何种情况下应移除装置,以避免因感染导致失败或移除。
研究设计与样本
- 回顾性分析大型神经调控实践中8年间40例因伤口并发症接受冲洗或部分装置挽救的患者。
- 共29例冲洗、10例部分装置移除、1例移除后更换。
- 考察年龄、性别、体重指数、吸烟状态、抗凝及装置类型等协变量。
主要发现
- 冲洗成功15/29例(51.7%),部分装置移除成功2/10例(20%),移除后更换失败(0/1)。
- 冲洗成功率有高于部分移除的趋势(P=0.08)。
- 冲洗成功者中,感染症状至冲洗的平均间隔为7.27±2.19天。
- 无人口学变量与冲洗失败可能性增加相关。
- 部分装置移除及手术部位存在脓性分泌物者冲洗失败率较高。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需进一步研究以确定何种情况下应移除装置,以避免因感染导致失败或移除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Wound complications are a prevalent concern for neuromodulation procedures. While removal of the device was recommended, attempts to salvage expensive hardware have become commonplace. We examine our management in wound issues to aid in providing guidance for these situations. METHODS: We identified 40 patients over an 8-year period in a large neuromodulation practice, who underwent washout or partial salvage of hardware. We examined the efficacy of washout and partial explants on the ability to salvage the implants. Covariates including age, sex, body mass index, smoking status, anticoagulation, and device type were considered. RESULTS: There were 29 washouts and 10 partial hardware removal cases. Washouts were successful in 15/29 cases (51.7%), partial hardware removal was successful in 2/10 cases (20%), and removal with replacement was not successful (0 of 1). Washouts tended to be more successful than partial removal procedures (P = 0.08). In cases of successful washout, the average duration between infectious symptoms and washout was 7.27 ± 2.19 days. None of the demographic variables were associated with increased likelihood of washout failure. CONCLUSIONS: Our results demonstrate a higher rate of washout failure in those who underwent partial device removal and in the presence of purulence at the surgical site. Further investigation must be conducted to determine the instances in which hardware removal is indicated to prevent failure or removal due to infection. Identification of these parameters will optimize therapeutic benefit and long-term financial impact.
引用
- Prabhala T, Figueroa F, Harland T, et al. The Use of Salvage Procedures for Wound Complications in Neuromodulation. World Neurosurg. 2022. PMID: 36529435. doi:10.1016/j.wneu.2022.12.071