切除范围与BRAF V600E突变状态决定儿童低级别胶质瘤术后肿瘤生长速度:单中心队列分析结果
该单中心回顾性队列分析对172例接受手术的儿童低级别胶质瘤患者中的107例不完全切除者进行术前及术后肿瘤生长速度(TGV)分析,发现平均术前TGV为0.264 cm3/月,第1、2、3次不完全切除后分别降至0.085、0.024、-0.016 cm3/月(p<0.001),切除范围与术后TGV降低相关(R=0.97,p<0.001),BRAF V600E突变型术后TGV显著高于野生型(0.123 vs 0.016 cm3/月,p=0.047)。
要点
- 不完全切除后儿童低级别胶质瘤生长速度显著减慢,且随多次切除进一步下降。
- 切除范围与术后TGV降低高度相关(R=0.97,p<0.001)。
- BRAF V600E突变型术后TGV显著高于野生型(0.123 vs 0.016 cm3/月,p=0.047)。
核心结论
- 数据提示广泛手术切除可能通过诱导肿瘤生长显著减慢而影响儿童低级别胶质瘤不完全切除后的生长动力学。
- BRAF V600E突变可能是术后TGV较高的危险因素。
研究设计与样本
- 单中心回顾性队列分析,共172例接受手术治疗的儿童低级别胶质瘤患者,其中107例(66%)接受不完全切除。
- 术前队列53例、术后队列94例,平均随访时间分别为40.2个月和60.1个月。
- 对共407次MRI扫描进行序贯三维MRI肿瘤体积测量以计算术前和术后TGV。
主要发现
- 平均术前TGV为0.264 cm3/月,第1、2、3次不完全切除后分别显著减速至0.085 cm3/月、0.024 cm3/月和-0.016 cm3/月(p<0.001)。
- 排除接受(新)辅助治疗的患者后结果仍显著。
- 切除范围与术后TGV降低相关(R=0.97,p<0.001)。
- BRAF V600E突变型低级别胶质瘤术后TGV显著高于BRAF野生型(0.123 cm3/月 vs 0.016 cm3/月,p=0.047)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Despite excellent long-term overall survival rates, pediatric low-grade gliomas (pLGG) show high variety of clinical behavior regarding progress or senescence post incomplete resection (IR). This study retrospectively analyzes tumor growth velocity (TGV) of pLGG before surgery and after IR to investigate the impact of surgical extent, tumor location and molecular BRAF status on postoperative residual tumor growth behavior. METHODS: Of a total of 172 patients with pLGG receiving surgical treatment, 107 underwent IR (66%). Fifty-three vs 94 patients could be included in the pre- and post-operative cohort, respectively, and were observed over a mean follow-up time of 40.2 vs 60.1 months. Sequential three-dimensional MRI-based tumor volumetry of a total of 407 MRI scans was performed to calculate pre- and postoperative TGV. RESULTS: Mean preoperative TGV of 0.264 cm3/month showed significant deceleration of tumor growth to 0.085 cm3/month, 0.024 cm3/month and -0.016 cm3/month after 1st, 2nd, and 3rd IR, respectively (p < 0.001). Results remained significant after excluding patients undergoing (neo)adjuvant treatment. Resection extent showed correlation with postoperative reduction of TGV (R = 0.97, p < 0.001). ROC analysis identified a residual cut-off tumor volume > 2.03 cm3 associated with a higher risk of progress post IR (sensitivity 78,6%, specificity 76.3%, AUC 0.88). Postoperative TGV of BRAF V600E-mutant LGG was significantly higher than of BRAF wild-type LGG (0.123 cm3/month vs. 0.016 cm3/month, p = 0.047). CONCLUSION: This data suggests that extensive surgical resection may impact pediatric LGG growth kinetics post incomplete resection by inducing a significant deceleration of tumor growth. BRAF-V600E mutation may be a risk factor for higher postoperative TGV.
引用
- Gorodezki D, Zipfel J, Queudeville M, et al. Resection extent and BRAF V600E mutation status determine postoperative tumor growth velocity in pediatric low-grade glioma: results from a single-center cohort analysis. J Neurooncol. 2022. PMID: 36319795. doi:10.1007/s11060-022-04176-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。