文献速递脑血管病外科

双LVIS Blue支架治疗梭形脑动脉瘤的结果

Results of Double Low-Profile Visualized Intraluminal Support Blue Stenting for the Treatment of Fusiform Cerebral Aneurysms.
PubMed 文献 · World Neurosurg · 2022-11-13

本研究分析了2016年3月至2020年7月间25例梭形脑动脉瘤患者接受双LVIS Blue支架置入的临床与血管造影结果,技术成功率100%,随访期间无死亡或迟发并发症,完全闭塞率84.0%,结论认为该技术有效且安全。

要点

  • 双LVIS Blue支架治疗梭形脑动脉瘤技术成功率为100%(25/25)。
  • 随访血管造影完全闭塞(O'Kelly-Marotta D)率为84.0%(21例)。
  • 随访期间无死亡或迟发并发症,无显著支架内狭窄或分支闭塞。

核心结论

  • 双LVIS Blue支架治疗梭形脑动脉瘤有效且安全。

研究设计与样本

  • 回顾性分析2016年3月至2020年7月间25例梭形脑动脉瘤患者,尝试双LVIS Blue支架置入,并复习病历与影像。

主要发现

  • 技术成功率为100%(25/25)。
  • 动脉瘤位于前循环6例(24.0%),后循环19例(76.0%)。
  • 术中血栓栓塞并发症1例(4.0%)。
  • 随访期(30.8 ± 14.2个月)无死亡或迟发并发症,平均血管造影随访时间28.2 ± 12.8个月。
  • 随访血管造影显示完全闭塞(O'Kelly-Marotta D)21例(84.0%),近完全闭塞(O'Kelly-Marotta C + 2匹配Kamran-Byrne 3级)2例(8.0%),闭塞分级恶化2例(8.0%),需再治疗1例(4.0%),无显著支架内狭窄或支架覆盖分支闭塞。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The flow diversion technique is increasingly used for reconstructive endovascular treatment of fusiform cerebral aneurysms. Double stenting with the Low-profile Visualized Intraluminal Support (LVIS) Blue stent is one of the flow diversion techniques. The aim of this study was to analyze the clinical and angiographic outcomes of LVIS Blue double stenting for fusiform cerebral aneurysms. METHODS: Between March 2016 and July 2020, double LVIS Blue stenting was attempted in 25 fusiform cerebral aneurysms. Patient medical records and radiological images were carefully reviewed. RESULTS: The technical success rate was 100% (25/25). Six aneurysms (24.0%) were located in the anterior circulation and 19 aneurysms (76.0%) were located in the posterior circulation. Intraprocedural thromboembolic complications occurred in 1 patient (4.0%). During the follow-up period (30.8 ± 14.2 months), there were no deaths or delayed complications. The mean angiographic follow-up duration was 28.2 ± 12.8 months. Follow-up angiography revealed complete obliteration (O'Kelly-Marotta D) in 21 (84.0%) patients and near-complete obliteration (O'Kelly-Marotta C + 2 matched with Kamran-Byrne grade 3) in 2 (8.0%) patients. Two patients (8.0%) showed worsening of obliteration grades. One (4.0%) patient required retreatment. There was no significant in-stent stenosis or branch occlusion covered by stents. CONCLUSIONS: Double stenting using LVIS Blue stents for the treatment of fusiform cerebral aneurysms is effective and safe.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Ban SP, Kwon OK, Kim YD, et al. Results of Double Low-Profile Visualized Intraluminal Support Blue Stenting for the Treatment of Fusiform Cerebral Aneurysms. World Neurosurg. 2022. PMID: 36379363. doi:10.1016/j.wneu.2022.11.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。