三维多模态融合影像与动脉内吲哚菁绿视频血管造影联合应用于脑动静脉畸形手术的疗效
本研究在12例脑动静脉畸形(AVM)患者中联合应用三维多模态融合影像与动脉内吲哚菁绿(ICG)视频血管造影,并与手术视图比较、由术者评估。结果显示联合技术比单一模态更有用,尤其在识别浅表供血动脉和估计畸形团范围方面有效。
要点
- ICG视频血管造影在所有病例中识别浅表供血动脉的评估均高。
- 三维多模态融合影像在所有病例中估计畸形团范围的评估均高。
- 联合两种技术比单一模态更有用,尤其在识别浅表供血动脉和估计畸形团范围方面。
核心结论
- 联合应用两种技术比每种模态单独使用在AVM手术中更有用。
- 联合技术在识别浅表供血动脉和估计畸形团范围方面特别有效。
- 该技术有望成为AVM手术的最佳工具。
研究设计与样本
- 研究在12例AVM患者中应用了两种技术。
- 两种图像与手术视图比较并由术者评估。
主要发现
- ICG视频血管造影在所有病例中识别浅表供血动脉的评估均高。
- AVM越复杂,三维多模态融合影像的评估越低。
- 三维多模态融合影像在所有病例中估计畸形团范围的评估均高,而ICG视频血管造影除一例外评估均低。
- ICG视频血管造影后获得的Flow 800分析可识别畸形团血流减少。
临床怎么用
- 作者认为联合两种技术可用于AVM手术,尤其在识别浅表供血动脉和估计畸形团范围方面。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: An understanding of the complex morphology of an arteriovenous malformation (AVM) is important for successful resection. We have previously reported the utility of intra-arterial indocyanine green (ICG) videoangiography for this purpose, but that method cannot detect the angioarchitecture covered by brain tissue. 3-dimensional (3D) multimodal fusion imaging is reportedly useful for this same purpose, but cannot always visualize the exact angioarchitecture due to poor source images and processing techniques. This study examined the results of utilizing both techniques in patients with AVMs. METHODS: Both techniques were applied in 12 patients with AVMs. Both images were compared with surgical views and evaluated by surgeons. RESULTS: Although evaluations for identifying superficial feeders by ICG videoangiography were high in all cases, the more complicated the AVM, the lower the evaluation by 3D multimodal fusion imaging. Conversely, evaluation of the estimated range of the nidus was high in all cases by 3D multimodal fusion imaging, but low in all but one case by ICG videoangiography. Nidus flow reduction was recognized by Flow 800 analysis obtained after ICG videoangiography. CONCLUSIONS: These results showed that utilizing both techniques together was more useful than each modality alone in AVM surgery. This was particularly effective in identifying superficial feeders and estimating the range of the nidus. This technique is expected to offer an optimal tool for AVM surgery.
引用
- Shimada K, Miyake K, Yamaguchi I, et al. Efficacy of Utilizing Both 3-Dimensional Multimodal Fusion Image and Intra-Arterial Indocyanine Green Videoangiography in Cerebral Arteriovenous Malformation Surgery. World Neurosurg. 2022. PMID: 36332776. doi:10.1016/j.wneu.2022.10.121
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。