经皮球囊压迫术中梅克尔腔形态、球囊形态与囊内压力的关系研究
该研究分析58例典型三叉神经痛行经皮球囊压迫术患者,术前用磁共振三维稳态采集快速成像薄层扫描序列重建分析梅克尔腔矢状面特征,术中连续记录梨形球囊形成时压力并测量球囊高度/长度比。结果显示囊内压力与梅克尔腔高度/长度比呈负相关,球囊高度/长度比与梅克尔腔高度/长度比无显著差异。
要点
- 囊内压力与梅克尔腔高度/长度比呈负相关。
- 球囊高度/长度比与梅克尔腔高度/长度比无显著差异。
- 术后57例疼痛即刻缓解,有效率98.27%(57/58)。
核心结论
- 球囊囊内压力与梅克尔腔高度/长度比呈负相关。
- 梨形球囊的个体化形成与梅克尔腔矢状面形态相关性小。
研究设计与样本
- 分析58例在本院行经皮球囊压迫术的典型三叉神经痛患者。
- 术前用磁共振三维稳态采集快速成像薄层扫描序列重建分析梅克尔腔矢状面特征。
- 术中连续记录梨形球囊形成时压力并测量球囊高度/长度比。
主要发现
- 术后57例疼痛即刻缓解,有效率98.27%(57/58)。
- 中位随访7.5个月内复发2例。
- 磁共振梅克尔腔分型:杵状型31.1%(18/58)、椭圆型58.6%(34/58)、扁平型10.3%(6/58)。
- 梅克尔腔高度/长度比较高时囊内压力较低。
- 球囊高度/长度比与梅克尔腔高度/长度比无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Percutaneous balloon compression is a safe, effective, and minimally invasive therapeutic method for trigeminal neuralgia. Intraoperatively precise compression after the formation of the pear-shaped balloon is the key to the expected effect. In this study, we assessed the relationship between the structure of Meckel's cavity and the shape and intracapsular pressure of the balloon by preoperative magnetic resonance. METHODS: We respectively analyzed 58 patients with typical trigeminal neuralgia who underwent percutaneous balloon compression surgery in our department. Reconstruction of magnetic resonance imaging 3-dimensional fast imaging employing steady-state acquisition thin-layer scanning sequence was also performed before the operation to analyze the sagittal features of Meckel's cavity. The pressure was recorded continuously when a pear-shaped balloon was forming during the operation. Meanwhile, the balloon height/length (h/l) ratio was measured. The relationship between Meckel's cavity shape, balloon shape, and pressure was analyzed by mentioned parameters. RESULTS: The pain of 57 patients was relieved immediately after the operation, and the effective rate was 98.27% (57 of 58); Recurrence in 2 cases within the median follow-up time (7.5 months). Meckel's cavity classification on magnetic resonance showed that the clubbing type, oval type, and flat type accounted for 31.1% (18 of 58), 58.6% (34 of 58), and 10.3% (6 of 58), respectively. The results demonstrated that the intracapsular pressure was low, while the h/l ratio of Meckel's cavity was relatively high. We also found the corresponding pressure results when the ratio was low. However, no significant difference was found between the balloon h/l ratio and Meckel's cavity h/l ratio. CONCLUSIONS: Intracapsular pressure of balloon is negatively correlated with the h/l ratio of Meckel's cavity. The individually differentiated formation of the pear-shaped balloon has little correlation with the sagittal shape of Meckel's cavity.
引用
- Shi J, Bo F, Pan R, et al. Research on the Relationship Between Meckel's Cavity Shape, Balloon Shape, and Intracapsular Pressure During Percutaneous Balloon Compression. World Neurosurg. 2022. PMID: 36243362. doi:10.1016/j.wneu.2022.10.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。