通过光谱和组织学显微镜评估随机选取的儿童脑肿瘤中的5-ALA荧光
研究纳入14例随机选取的儿童脑肿瘤患者,术前给予5-ALA(20 mg/kg),用手术显微镜和手持光谱探头检测荧光。显微镜下仅2例可见模糊荧光,探头在5例中检测到肿瘤内荧光,9例无荧光,未观察到临床或实验室不良事件。
要点
- 5-ALA在儿童脑肿瘤中显微镜下荧光模糊,探头检测阳性5例。
- 9例儿童肿瘤及皮肤均无荧光,有荧光者均大于9岁。
- 未观察到5-ALA相关的临床副作用或实验室不良事件。
核心结论
- 在本研究中,荧光未能用于引导手术,无论是用手术显微镜还是手持探头。
- 9例儿童未辨别出荧光,有明显荧光的儿童均大于9岁。
- 5-ALA被认为在儿童中应用是安全的。
研究设计与样本
- 研究纳入14例随机选取的年龄4-17岁、新近经MRI证实的脑肿瘤儿童,术前未根据疑似诊断进行选择。
- 所有患者术前接受5-ALA 20 mg/kg,口服或经胃管给药。
- 用显微镜和探头检测肿瘤内荧光,并测量前臂皮肤荧光,分析血液样本并监测潜在临床副作用。
主要发现
- 组织病理学显示7例低级别胶质瘤、4例髓母细胞瘤、1例弥漫性内生性桥脑胶质瘤、1例胶质母细胞瘤和1例非典型脑膜瘤。
- 显微镜下2例可见模糊荧光,探头在5例患者中检测到肿瘤内荧光,包括上述2例显微镜下模糊荧光者。
- 3例年龄最大的儿童皮肤中出现PpIX荧光,9例儿童肿瘤和皮肤均无荧光。
- 未观察到临床副作用或实验室不良事件。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Fluorescence-guided surgery applying 5-aminolevulinic acid (5-ALA) in high-grade gliomas is an established method in adults. In children, results have so far been ambiguous. The aim of this study was to investigate 5-ALA-induced fluorescence in pediatric brain tumors by using the surgical microscope and a spectroscopic hand-held probe. METHODS: Fourteen randomly selected children (age 4-17) with newly MRI-verified brain tumors were included. No selection was based on the suspected diagnosis prior to surgery. All patients received 5-ALA (20 mg /kg) either orally or via a gastric tube prior to surgery. Intratumoral fluorescence was detected with the microscope and the probe. Moreover, fluorescence in the skin of the forearm was measured. Histopathology samples revealed seven low-grade gliomas, four medulloblastomas, one diffuse intrinsic pontine glioma, one glioblastoma and one atypical meningioma. Blood samples were analyzed, and potential clinical side effects were monitored. RESULTS: Microscopically, vague fluorescence was visible in two patients. Intratumoral fluorescence could be detected in five patients with the probe, including the two patients with vague microscopic fluorescence. Three of the oldest children had PpIX fluorescence in the skin. Nine children did not show any fluorescence in the tumor or in the skin. No clinical side effects or laboratory adverse events were observed. CONCLUSION: Fluorescence could not be used to guide surgery in this study, neither with the surgical microscope nor with the hand-held probe. In nine children, no fluorescence was discerned and children with noticeable fluorescence were all older than nine years. 5-ALA was considered safe to apply in children.
引用
- Milos P, Haj-Hosseini N, Hillman J, et al. 5-ALA fluorescence in randomly selected pediatric brain tumors assessed by spectroscopy and surgical microscope. Acta Neurochir (Wien). 2022. PMID: 36242636. doi:10.1007/s00701-022-05360-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。