清醒与睡眠状态下介入磁共振成像引导脑深部电刺激治疗帕金森病的靶向准确性与临床结局:加州大学旧金山分校经验
该回顾性研究比较了2013至2019年在本机构接受清醒或介入磁共振成像(iMRI)引导下丘脑底核或苍白球内侧部脑深部电刺激(DBS)的218例帕金森病患者,发现iMRI组径向误差更小、电极穿刺次数更少,但统一帕金森病评定量表变化相似,清醒组左旋多巴等效日剂量减少更明显,有效刺激触点、副作用阈值和并发症率相似。
要点
- iMRI组径向误差1.27±0.72 mm,清醒组1.59±0.96 mm,P<.01。
- iMRI组电极穿刺次数1.0±0.16,清醒组1.2±0.41,P<.01。
- 清醒组左旋多巴等效日剂量减少多于iMRI组,P<.01。
核心结论
- iMRI引导DBS可能比清醒DBS获得更准确的电极放置,但两种手术方式的临床结局相似。
- 患者偏好和外科医生对特定DBS技术的经验应是决定最佳植入方法的主要因素。
研究设计与样本
- 回顾性综述,纳入2013年至2019年在本机构接受清醒或iMRI引导下丘脑底核或苍白球内侧部DBS的帕金森病患者218例。
主要发现
- iMRI组径向误差1.27±0.72 mm,清醒组1.59±0.96 mm,P<.01。
- iMRI组电极穿刺次数1.0±0.16,清醒组1.2±0.41,P<.01。
- 统一帕金森病评定量表变化在两种方式间相似。
- 清醒组左旋多巴等效日剂量减少大于iMRI组,P<.01,多变量分析归因于清醒组丘脑底核病例更多。
- 有效临床刺激触点、副作用阈值和并发症率在两种方式间相似。
临床怎么用
- 患者偏好和外科医生对特定DBS技术的经验应是确定最佳DBS植入方法的主要因素。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Interventional MRI (iMRI)-guided implantation of deep brain stimulator (DBS) leads has been developed to treat patients with Parkinson's disease (PD) without the need for awake testing. OBJECTIVE: Direct comparisons of targeting accuracy and clinical outcomes for awake stereotactic with asleep iMRI-DBS for PD are limited. METHODS: We performed a retrospective review of patients with PD who underwent awake or iMRI-guided DBS surgery targeting the subthalamic nucleus or globus pallidus interna between 2013 and 2019 at our institution. Outcome measures included Unified Parkinson's Disease Rating Scale Part III scores, levodopa equivalent daily dose, radial error between intended and actual lead locations, stimulation parameters, and complications. RESULTS: Of the 218 patients included in the study, the iMRI cohort had smaller radial errors (iMRI: 1.27 ± 0.72 mm, awake: 1.59 ± 0.96 mm, P < .01) and fewer lead passes (iMRI: 1.0 ± 0.16, awake: 1.2 ± 0.41, P < .01). Changes in Unified Parkinson's Disease Rating Scale were similar between modalities, but awake cases had a greater reduction in levodopa equivalent daily dose than iMRI cases ( P < .01), which was attributed to the greater number of awake subthalamic nucleus cases on multivariate analysis. Effective clinical contacts used for stimulation, side effect thresholds, and complication rates were similar between modalities. CONCLUSION: Although iMRI-DBS may result in more accurate lead placement for intended target compared with awake-DBS, clinical outcomes were similar between surgical approaches. Ultimately, patient preference and surgeon experience with a given DBS technique should be the main factors when determining the "best" method for DBS implantation.
引用
- Lee AT, Han KJ, Nichols N, et al. Targeting Accuracy and Clinical Outcomes of Awake versus Asleep Interventional Magnetic Resonance Imaging-Guided Deep Brain Stimulation for Parkinson's Disease: The University of California, San Francisco Experience. Neurosurgery. 2022. PMID: 36069560. doi:10.1227/neu.0000000000002111
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。