基于影像编程的丘脑前核脑深部电刺激临床结局
这项回顾性研究评估7例接受丘脑前核脑深部电刺激(ANT DBS)的耐药性癫痫患者,依据MRI直视下将电极触点编程至最靠近ANT-乳头丘脑束(ANT-MMT)交界处。7例中4例(57.1%)癫痫发作频率减少≥50%;4例应答者均至少有一个触点位于ANT-MMT交界1 mm以内,而3例未达50%改善者均无触点位于该交界1 mm以内。触点距ANT-MMT交界越近,癫痫改善越明显(R2=0.62,p=0.04);触点距ANT核任何边界均与癫痫改善无显著相关(R2=0.24,p=0.26)。
要点
- 7例ANT DBS患者中4例(57.1%)发作频率减少≥50%。
- 4例应答者均至少1个触点距ANT-MMT交界≤1 mm,3例未达50%改善者均无此类触点。
- 触点距ANT-MMT交界越近癫痫改善越明显(R2=0.62,p=0.04),距ANT边界无显著相关(R2=0.24,p=0.26)。
核心结论
- 数据支持以下假说:仅靠近ANT本身与癫痫发作减少不相关,而靠近ANT-MMT交界则与发作减少相关。
- 这些发现支持ANT DBS中直接靶向的重要性以及影像引导编程的价值。
- 作者为未来采用ANT-MMT交界进行直接手术靶向的前瞻性试验提供了支持性证据。
研究设计与样本
- 回顾性研究,评估已接受ANT DBS电极植入、并依据直接MRI可视化将设备编程至最靠近ANT-MMT交界处刺激的患者。
- 比较应答者(癫痫发作频率减少≥50%)与非应答者之间活动电极与ANT及ANT-MMT交界的距离。
- 采用线性回归评估癫痫发作减少百分比与至ANT及ANT-MMT交界距离的关系。
主要发现
- 7例患者中4例(57.1%)癫痫发作减少≥50%。
- 4例应答者均至少有一个触点位于ANT-MMT交界1 mm以内,而3例癫痫改善<50%的患者均无触点位于ANT-MMT交界1 mm以内。
- 4例应答者触点位置较3例非应答者更靠近ANT-MMT交界:距MMT平均距离应答者左侧0.7 mm、右侧0.6 mm,非应答者左侧3.0 mm、右侧2.3 mm。
- 电极触点与ANT核内任何一点的靠近程度与癫痫发作减少不相关。
- 癫痫改善越大与触点位置越靠近ANT-MMT交界相关(R2=0.62,p=0.04);癫痫改善与触点靠近ANT任何边界的程度无显著相关(R2=0.24,p=0.26)。
临床怎么用
- 原文未据此给出推荐。
- 作者认为这些发现支持ANT DBS中直接靶向的重要性以及影像引导编程的价值。
- 作者为未来采用ANT-MMT交界进行直接手术靶向的前瞻性试验提供了支持性证据。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The authors hypothesized that the proximity of deep brain stimulator contacts to the anterior thalamic nucleus-mammillothalamic tract (ANT-MMT) junction determines responsiveness to treatment with ANT deep brain stimulation (DBS) in drug-resistant epilepsy and conducted this study to test that hypothesis. METHODS: This retrospective study evaluated patients who had undergone ANT DBS electrode implantation and whose devices were programmed to stimulate nearest the ANT-MMT junction based on direct MRI visualization. The proximity of the active electrode to the ANT and the ANT-MMT junction was compared between responders (≥ 50% reduction in seizure frequency) and nonresponders. Linear regression was performed to assess the percentage of seizure reduction and distance to both the ANT and the ANT-MMT junction. RESULTS: Four (57.1%) of 7 patients had ≥ 50% reduction in seizures. All 4 responders had at least one contact within 1 mm of the ANT-MMT junction, whereas the 3 patients with < 50% seizure improvement did not have a contact within 1 mm of the ANT-MMT junction. Additionally, the 4 responders demonstrated contact positioning closer to the ANT-MMT junction than the 3 nonresponders (mean distance from MMT: 0.7 mm on the left and 0.6 mm on the right in responders vs 3.0 mm on the left and 2.3 mm on the right in nonresponders). However, proximity of the electrode contact to any point in the ANT nucleus did not correlate with seizure reduction. Greater seizure improvement was correlated with a contact position closer to the ANT-MMT junction (R2 = 0.62, p = 0.04). Seizure improvement was not significantly correlated with proximity of the contact to any ANT border (R2 = 0.24, p = 0.26). CONCLUSIONS: Obtained using a combination of direct visualization and targeted programming of the ANT-MMT junction, data in this study support the hypothesis that proximity to the ANT alone does not correlate with seizure reduction in ANT DBS, whereas proximity to the ANT-MMT junction does. These findings support the importance of direct targeting in ANT DBS, as well as imaging-informed programming. Additionally, the authors provide supportive evidence for future prospective trials using ANT-MMT junction for direct surgical targeting.