文献速递功能神经外科

术中锥形束CT联合金属伪影减少技术评估脑深部电刺激术中电极位置及颅内结构

Intraoperative cone-beam CT with metal artifact reduction for assessment of the electrode position and the intracranial structures during deep brain stimulation procedure.
PubMed 文献 · Acta Neurochir (Wien) · 2022-07-18

本病例系列纳入2019年11月至2020年12月在本机构接受脑深部电刺激(DBS)的10例帕金森病(PD)患者,分析其中9例(双侧8例、单侧1例)的影像。回顾性评估术中锥形束CT联合金属伪影减少技术(intraCBCTwM)与不联合该技术(intraCBCTwoM)的伪影指数(AI),并与常规术后CT(post-CT)比较电极尖端欧几里得距离差。结果显示intraCBCTwM的AI显著低于intraCBCTwoM(P < 0.01),且intraCBCTwM与post-CT融合图像中电极尖端的平均欧几里得距离显著短于intraCBCTwoM(P < 0.05)。作者认为intraCBCTwM在评估DBS术中植入电极位置及颅内结构方面较intraCBCTwoM更有效、更准确。

要点

  • intraCBCTwM的伪影指数显著低于intraCBCTwoM(P < 0.01)。
  • intraCBCTwM与post-CT融合图像中电极尖端平均欧几里得距离显著短于intraCBCTwoM(P < 0.05)。
  • 作者认为intraCBCTwM在评估DBS术中电极位置及颅内结构方面较intraCBCTwoM更有效、更准确。

核心结论

  • 作者认为intraCBCTwM在评估DBS术中植入电极位置及颅内结构方面较intraCBCTwoM更有效、更准确。

研究设计与样本

  • 本病例系列纳入2019年11月至2020年12月在本机构接受DBS的10例PD患者,分析其中9例(双侧8例、单侧1例)的影像。
  • 回顾性评估intraCBCTwM或intraCBCTwoM以及常规post-CT的伪影指数(AI),采用植入电极周围感兴趣区域的标准差与背景噪声计算。
  • 比较intraCBCTwM与intraCBCTwoM各自融合图像中基于post-CT的电极尖端欧几里得距离差。

主要发现

  • intraCBCTwM的AI显著低于intraCBCTwoM(P < 0.01)。
  • intraCBCTwM与post-CT融合图像中电极尖端的平均欧几里得距离显著短于intraCBCTwoM(P < 0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In deep brain stimulation (DBS) for Parkinson's disease (PD), the clinical outcome largely depends on the appropriate position of the electrode implanted in the targeted structure. In intraoperative cone-beam computed tomography (CT) performed for the evaluation of the electrode position, the metal artifact induced by the implanted electrode can prevent the precise localization of the electrode. Metal artifact reduction (MAR) techniques have been recently developed that can dramatically improve the visualization of objects by reducing metal artifacts after performing cone-beam CT. Hence, in this case series, we attempted to clarify the usefulness and accuracy of intraoperative cone-beam CT with MAR (intraCBCTwM) by comparing with both intraoperative cone-beam CT without MAR (intraCBCTwoM) and conventional postoperative CT (post-CT) for the assessment of the implanted electrode position and the intracranial structures during DBS procedures. METHODS: Between November 2019 and December 2020, 10 patients with PD who underwent DBS at our institution were recruited, and the images of 9 patients (bilateral: n = 8, unilateral: n = 1) were analyzed. The artifact index (AI) in intraCBCTwM or intraCBCTwoM, and conventional post-CT were retrospectively assessed using the standard deviation of the region-of-interest around the implanted electrodes and background noise. Additionally, the Euclidean distances gap of electrode tip based on post-CT in each fusion image was compared between intraCBCTwM and intraCBCTwoM. RESULTS: The AI was significantly lower in intraCBCTwM than in intraCBCTwoM (P < 0.01). The mean Euclidean distance between the tip of the electrode in intraCBCTwM and in post-CT was significantly shorter compared to that in intraCBCTwoM (P < 0.05). CONCLUSIONS: The results reported here suggest that intraCBCTwM is a more useful and accurate method than intraCBCTwoM to assess the implanted electrode position and intracranial structures during DBS.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Kawasaki T, Kikuchi T, Otani K, et al. Intraoperative cone-beam CT with metal artifact reduction for assessment of the electrode position and the intracranial structures during deep brain stimulation procedure. Acta Neurochir (Wien). 2022. PMID: 35851925. doi:10.1007/s00701-022-05313-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。