文献速递脑血管病外科

旁眼动脉段动脉瘤手术中采用C臂透视与颈总动脉直接穿刺的术中血管造影

Intraoperative Angiogram Using C-Arm Fluoroscopy and Direct Common Carotid Artery Puncture During Surgical Treatment of Paraclinoid Aneurysms.
PubMed 文献 · World Neurosurg · 2022-06-29

该研究描述了在旁眼动脉段动脉瘤手术中,利用颈部切口直接穿刺颈动脉、在普通手术室以单平面C臂透视完成术中血管造影的简易方法。共纳入5例患者(2例蛛网膜下腔出血、2例未破裂动脉瘤伴蛛网膜下腔出血史、1例未破裂动脉瘤),术中图像质量均足以判断动脉瘤闭塞完全性及载瘤动脉与分支血管通畅性,无术后梗死及与造影相关并发症。

要点

  • 经颈部切口直接穿刺颈动脉,可在普通手术室用C臂完成术中血管造影。
  • 5例术中图像均足以判断动脉瘤闭塞完全性及载瘤动脉、分支血管通畅性。
  • 无术后梗死,无与术中血管造影相关的并发症。

核心结论

  • 采用直接颈动脉穿刺的术中血管造影可在配备C臂的普通手术室完成,无需经主动脉弓插管及大血管选择。

研究设计与样本

  • 单中心研究,纳入需暴露颈部颈动脉行旁眼动脉段动脉瘤手术的患者5例,术中经颈部切口直接穿刺颈动脉,使用单平面C臂透视行术中血管造影。

主要发现

  • 5例患者中2例为蛛网膜下腔出血,2例为未破裂动脉瘤伴蛛网膜下腔出血史,1例为未破裂动脉瘤。
  • 动脉瘤类型包括2例颈内动脉血泡样动脉瘤、2例眼动脉瘤、1例垂体上动脉瘤。
  • 所有病例术中图像质量均足以判断动脉瘤闭塞完全性以及载瘤动脉和分支血管通畅性。
  • 无术后梗死,无与术中血管造影相关的并发症。

临床怎么用

  • 对于需暴露颈部颈动脉以控制近端的旁眼动脉段动脉瘤手术,可采用经颈部切口直接穿刺颈动脉、以C臂透视行术中血管造影,从而避免主动脉弓插管。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intraoperative angiography (IOA) has been shown to be a useful adjunct in surgical treatment of cerebral aneurysms. However, its use can be limited by hybrid operating room availability. On the other hand, the use of C-arm fluoroscopy can add challenges to IOA during navigation of the aortic arch and selection of the great vessels. We aimed to describe a simple method of IOA that can be applied during surgery of paraclinoid aneurysms and can be performed in a normal operating room without the need to navigate the aortic arch. METHODS: In patients undergoing surgery for paraclinoid aneurysms with need for cervical carotid artery exposure, IOA was performed using a single plane C-arm fluoroscopy unit after direct puncture of the carotid artery. RESULTS: Five patients were included: 2 with subarachnoid hemorrhage, 2 with unruptured aneurysm and history of subarachnoid hemorrhage, and 1 with unruptured aneurysm. There were 2 internal carotid blister aneurysms, 2 ophthalmic artery aneurysms, and 1 superior hypophyseal artery aneurysm. IOA was performed using direct carotid puncture through the neck incision required for proximal control. In all cases, intraoperative images were of sufficient quality to determine the completeness of aneurysm occlusion as well as parent and branching vessel patency. There were no postoperative infarctions and no complications related to IOA. CONCLUSIONS: IOA using direct carotid puncture can be performed in a standard operating room with the use of a C-arm, eliminating the need to catheterize the great vessels of the aortic arch.