全内镜下腰椎椎间融合术与管状牵开器系统微创经椎间孔腰椎椎间融合术的回顾性对照研究
本研究回顾性比较了2018年8月至2020年8月间70例单节段腰椎退行性疾病患者接受全内镜下腰椎椎间融合术(FE-LIF)或管状牵开器系统微创经椎间孔腰椎椎间融合术(MIS-TLIF)的安全性和疗效。32例接受FE-LIF,38例接受MIS-TLIF,两组均无并发症;FE-LIF组辐射暴露更高、手术时间更长、出血更少(P < 0.05);两组术后疼痛和ODI评分均显著改善(P < 0.01),1年随访时神经根感觉运动功能均显著恢复(P < 0.05),MacNab评分无显著差异;FE-LIF组椎间融合率按Mannion融合分类显著优于MIS-TLIF组。
要点
- FE-LIF与MIS-TLIF术后疼痛、ODI及神经功能均显著改善,MacNab评分无显著差异。
- FE-LIF组辐射暴露更高、手术时间更长、出血更少(P < 0.05)。
- 按Mannion融合分类,FE-LIF组椎间融合率显著优于MIS-TLIF组。
核心结论
- FE-LIF安全、有效且微创,临床疗效与MIS-TLIF相同,但手术时间更长且辐射暴露增加。
研究设计与样本
- 回顾性对照研究,纳入2018年8月至2020年8月共70例单节段腰椎退行性疾病患者,32例接受FE-LIF,38例接受管状牵开器系统MIS-TLIF。
主要发现
- FE-LIF组辐射暴露高于MIS-TLIF组、手术时间长于MIS-TLIF组、出血少于MIS-TLIF组(P < 0.05)。
- 两组术后腰痛和腿痛均显著缓解,ODI评分均大幅改善(P < 0.01)。
- 两组1年随访时神经根感觉和运动功能均显著恢复(P < 0.05),MacNab评分两组间无显著差异。
- 按Mannion融合分类,FE-LIF组椎间融合率显著优于MIS-TLIF组。
- 所有患者均无明显并发症,术后腰椎MRI显示神经减压充分。
关键数值与推荐
- FE-LIF组辐射暴露高于MIS-TLIF组、手术时间长于MIS-TLIF组、出血少于MIS-TLIF组(P < 0.05)。
- 两组术后ODI评分均大幅改善(P < 0.01)。
- 两组1年随访时神经根感觉和运动功能均显著恢复(P < 0.05)。
- MacNab评分两组间无显著差异。
- 按Mannion融合分类,FE-LIF组椎间融合率显著优于MIS-TLIF组。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to compare the safety and clinical efficacy of full-endoscopic lumbar interbody fusion (FE-LIF) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). METHODS: A total of 70 patients with single-level lumbar degenerative diseases underwent FE-LIF or MIS-TLIF with a tubular retractor system from August 2018 to August 2020. Postoperatively, the efficacy and safety were compared using several clinical and radiological indices. RESULTS: A total of 32 patients underwent FE-LIF and 38 received MIS-TLIF with a tubular retractor system, and all patients had no apparent complications. The FE-LIF group had higher radiation exposure, longer operation time, and less bleeding than the MIS-TLIF group (P < 0.05). Postoperative lumbar magnetic resonance imaging showed that the nerve decompression was sufficient. The pain in the lower back and legs was significantly relieved, and the Oswestry Disability Index (ODI) score was greatly improved after surgery (P < 0.01) in both the groups. The sensory and motor functions of nerve roots were remarkably recovered in both the groups at the 1-year follow-up (P < 0.05), and there was no significant difference in MacNab scores between the 2 groups. As per Mannion's fusion classification, the interbody fusion rate was significantly better in the FE-LIF group than in the MIS-TLIF group. CONCLUSIONS: FE-LIF, which is safe, effective, and minimally invasive, exhibits the same clinical efficacy as MIS-TLIF but with longer operation time and increased radiation exposure.
引用
- Wang JC, Cao Z, Li ZZ, et al. Full-Endoscopic Lumbar Interbody Fusion Versus Minimally Invasive Transforaminal Lumbar Interbody Fusion with a Tubular Retractor System: A Retrospective Controlled Study. World Neurosurg. 2022. PMID: 35752422. doi:10.1016/j.wneu.2022.06.083
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。