文献速递脑血管病外科

经桡动脉入路动脉瘤栓塞术的可行性与安全性:系统综述与Meta分析

Feasibility and Safety of Transradial Aneurysm Embolization: A Systematic Review and Meta-Analysis.
PubMed 文献 · World Neurosurg · 2022-05-30

该系统综述与Meta分析评估经桡动脉入路(TRA)行颅内动脉瘤栓塞的可行性、成功率与并发症。纳入24项研究共1283例(85.9%)TRA及122例(8.2%)远端TRA栓塞。18项研究合并成功率为93.5%(95%CI 91.1%-95.8%),血栓栓塞、出血及入路部位并发症率均较低,结论认为TRA下多种栓塞技术可行且并发症少。

要点

  • 18项研究Meta分析示TRA动脉瘤栓塞合并成功率为93.5%(95%CI 91.1%-95.8%)
  • 合并血栓栓塞并发症率0.5%(95%CI 0.1%-0.9%),出血并发症率0.5%(95%CI 0.1%-0.9%)
  • 入路部位并发症率0.8%(95%CI 0.3%-1.3%),TRA下多种栓塞技术可行且并发症低

核心结论

  • 经桡动脉入路使用多种栓塞技术治疗颅内动脉瘤是可行的,且入路部位及术中并发症发生率低。

研究设计与样本

  • 系统检索PubMed、Scopus和Embase中经桡动脉入路行颅内动脉瘤栓塞的研究,采用随机效应模型合并手术成功率和并发症率。
  • 共纳入24项研究,包含1283例(85.9%)经桡动脉入路和122例(8.2%)远端经桡动脉入路动脉瘤栓塞操作。

主要发现

  • 18项研究Meta分析合并成功率为93.5%(95%CI 91.1%-95.8%)。
  • 合并血栓栓塞并发症率为0.5%(95%CI 0.1%-0.9%),出血并发症率为0.5%(95%CI 0.1%-0.9%),入路部位并发症率为0.8%(95%CI 0.3%-1.3%)。
  • 1项研究(4.3%)仅使用7-French指引导管,多数研究使用6-French指引导管(23项中22项,95.7%),其中4项研究(17.4%)将其纳入经无鞘8-French系统的三轴配置,2项研究(8.7%)使用7-French指引导管,1项研究(4.3%)使用8-French鞘。
  • 栓塞技术包括血流导向装置置入451例(39.1%)、弹簧圈栓塞376例(32.6%)、支架辅助弹簧圈栓塞127例(11.0%)、球囊辅助弹簧圈栓塞104例(9.0%)、Woven EndoBridge系统50例(4.3%)及血流导向装置置入联合弹簧圈栓塞42例(3.6%)。

临床怎么用

  • 原文结论认为经桡动脉入路使用多种栓塞技术治疗颅内动脉瘤可行,且入路部位及术中并发症发生率低;原文未据此给出具体推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Use of the transradial access (TRA) approach for neuroendovascular procedures has been increasing in recent years. Our aim is to assess the feasibility, success rate, and complications associated with TRA for intracranial aneurysm embolization. METHODS: PubMed, Scopus, and Embase were systematically searched for studies using TRA for intracranial aneurysm embolization. Random-effects models were used to obtain pooled rates of procedural success and complications. RESULTS: Twenty-four studies comprising 1283 (85.9%) TRA and 122 (8.2%) distal TRA aneurysm embolization procedures were included. The pooled success rate of the 18 studies in the meta-analysis was 93.5% (95% confidence interval [CI], 91.1%-95.8%). The pooled thromboembolic complication rate was 0.5% (95% CI, 0.1%-0.9%), the hemorrhagic complication rate was 0.5% (95% CI, 0.1%-0.9%), and the access site complication rate was 0.8% (95% CI, 0.3%-1.3%). One study (4.3%) used exclusively a 7-French guide catheter, and most used a 6-French guide catheter (22 of 23 studies, 95.7%), which was further incorporated as part of a triaxial configuration through a sheathless 8-French system in 4 studies (17.4%), 7-French guide catheter in 2 studies (8.7%), and 8-French sheath in 1 study (4.3%). The embolization techniques used were flow diverter placement in 451 cases (39.1%), coiling in 376 (32.6%), stent-assisted coiling in 127 (11.0%), balloon-assisted coiling in 104 (9.0%), Woven EndoBridge system in 50 (4.3%), and flow diverter placement plus coiling in 42 (3.6%). CONCLUSIONS: Treating intracranial aneurysms using various embolization techniques through TRA is feasible and associated with low access site and intraoperative complications.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Alkhars H, Haq W, Al-Tayeb A, et al. Feasibility and Safety of Transradial Aneurysm Embolization: A Systematic Review and Meta-Analysis. World Neurosurg. 2022. PMID: 35654332. doi:10.1016/j.wneu.2022.05.112

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。