视神经鞘脑膜瘤的放疗与放射外科治疗:20项研究的国际系统综述与Meta分析
该系统综述与Meta分析纳入20项研究共444例视神经鞘脑膜瘤(ONM)患者,评估放疗(RT)后视力(VA)与视野(VF)稳定或改善及影像学局部控制(LC)。估计LC率为99.8%,VA稳定或改善者为89.7%,VF稳定或改善者为93.3%;肿瘤总体积(GTV)与VA显著相关。
要点
- 放疗后估计影像学局部控制率达99.8%(95%CI 98.3%-100%)。
- 估计89.7%患者视力稳定或改善,93.3%患者视野稳定或改善。
- 估计放射性视网膜病变发生率为7.2%,干眼症为10.1%。
核心结论
- 放疗耐受性良好,可获得极佳的局部控制;近90%患者视力与视野稳定或改善;较大ONM与较差的视力相关。
研究设计与样本
- 采用PICOS/PRISMA/MOOSE筛选标准进行国际系统综述与Meta分析,纳入20项已发表研究、共444例ONM患者。
- 主要结局为末次随访时视力稳定或改善及影像学局部控制;次要结局为放射性视网膜病变、干眼症发生率及视野稳定或改善。
- 采用DerSimonian and Laird法的加权随机效应Meta分析估计效应量,并用混合效应回归模型分析GTV与结局的相关性。
主要发现
- 估计局部控制率为99.8%(95%CI 98.3%-100%)。
- 估计视力稳定或改善比例为89.7%(95%CI 86.2%-92.4%),视野稳定或改善比例为93.3%(95%CI 89.5%-95.8%)。
- 估计放射性视网膜病变发生率为7.2%,干眼症发生率为10.1%。
- GTV与视力显著相关(P=0.014),GTV为2.0、3.0、4.0 cm3时估计视力稳定或改善率分别为96.4%、91.4%、80.5%。
关键数值与推荐
- 局部控制率99.8%(95%CI 98.3%-100%)。
- 视力稳定或改善比例89.7%(95%CI 86.2%-92.4%)。
- 视野稳定或改善比例93.3%(95%CI 89.5%-95.8%)。
- 放射性视网膜病变发生率7.2%,干眼症发生率10.1%。
- GTV与视力相关P=0.014;GTV 2.0、3.0、4.0 cm3对应的视力稳定或改善率分别为96.4%、91.4%、80.5%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Optic nerve sheath meningiomas (ONMs) are often managed with radiotherapy (RT) with the goal of achieving radiographic local control (LC) and preventing deterioration of visual acuity (VA). We aimed to perform a systematic review and meta-analysis of outcomes for patients with ONM treated with RT. METHODS: The PICOS/PRISMA/MOOSE selection criteria were used to identify studies. Primary outcomes were stable or improved VA and radiographic LC at last follow-up. The secondary outcomes were incidences of radiation-induced retinopathy and xerophthalmia and stable or improved visual fields (VFs). Weighted random-effects meta-analyses using the DerSimonian and Laird methods were conducted to characterize effect sizes. Mixed-effects regression models were used to examine potential correlations between gross tumor volume (GTV) and outcomes. RESULTS: In total, 444 patients with ONM across 20 published studies were included. The estimated LC rate was 99.8% (95% confidence interval [CI], 98.3%-100%), and the estimated proportion of patients with stable or improved VA or VF was 89.7% (95% CI, 86.2%-92.4%) and 93.3% (95% CI, 89.5%-95.8%), respectively. Estimated incidences of radiation-induced retinopathy and xerophthalmia were 7.2% and 10.1%, respectively. GTV was significantly associated with VA (P = 0.014) with estimated VA rates of 96.4%, 91.4%, and 80.5% for GTVs of 2.0, 3.0, and 4.0 cm3, respectively. CONCLUSIONS: RT was well tolerated, with excellent LC achieved. Nearly 90% of patients noted either stability or improvement in VA and VF. Larger ONMs were associated with poorer VA.
引用
- Vaishnav YJ, Singh R, Didwania P, et al. Radiotherapy and Radiosurgery in the Management of Optic Nerve Sheath Meningiomas: An International Systematic Review and Meta-Analysis of Twenty Studies. World Neurosurg. 2022. PMID: 35609728. doi:10.1016/j.wneu.2022.05.064
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。