文献速递功能神经外科

难治性抑郁症脑深部电刺激的长期结果:结局分析及其与电极位置和电参数的相关性

Long-Term Results of Deep Brain Stimulation for Treatment-Resistant Depression: Outcome Analysis and Correlation With Lead Position and Electrical Parameters.
PubMed 文献 · Neurosurgery · 2022-01-01

17例难治性抑郁症患者接受胼胝体下扣带回脑深部电刺激(SCG-DBS),5年随访中按症状改善分为优秀应答(≥80%)、中等应答(≥50%-79%)和不良应答(<50%)三类;活跃触点坐标与总电能量输出均与临床结局无相关性;内侧Brodmann 10区是最常刺激区域,小钳是最常被调控的纤维束。

要点

  • SCG-DBS对部分难治性抑郁症患者明确有效,5年随访见三类应答轨迹。
  • 活跃触点坐标在区域内高度变异,且与临床结局无相关性。
  • 电参数(总电能量输出)与临床结局未见相关性。

核心结论

  • SCG-DBS对部分难治性抑郁症患者明确有效。
  • 活跃触点坐标在区域内高度变异,且与电参数一样似乎与临床结局无相关性。
  • 本系列中内侧Brodmann 10区和小钳分别是最常靶向的区域和最常被调控的通路。

研究设计与样本

  • 17例难治性抑郁症患者接受胼胝体下扣带回脑深部电刺激(SCG-DBS),记录人口学和基线特征。
  • 采用17项汉密尔顿抑郁量表评估治疗反应。
  • 计算活跃触点的前连合-后连合坐标和总电能量输出,并与临床结局进行相关性分析。
  • 对 responders 进行个体化纤维束示踪分析以识别被调控的通路。

主要发现

  • 纳入12名女性(70.6%)和5名男性(29.4%),中位年龄48岁(范围34-70岁)。
  • 5年随访中根据症状改善观察到3种主要临床轨迹:优秀应答(≥80%)、中等应答(≥50%-79%)和不良应答(<50%)。
  • 活跃触点坐标和总电能量输出与临床结局均无相关性。
  • 内侧Brodmann 10区是最常被刺激的区域,小钳是最常被调控的纤维束。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term efficacy and mechanisms of action of deep brain stimulation (DBS) for treatment-resistant depression (TRD) are under investigation. OBJECTIVE: To compare long-term outcomes with active electrode's coordinates and its electrical parameters in patients with TRD treated with DBS in the subgenual cingulate gyrus (SCG-DBS). METHODS: Seventeen patients with TRD underwent SCG-DBS. Demographic and baseline characteristics were recorded. The 17-item Hamilton Depression Rating Scale was used to measure the response to the therapy. The anterior commissure-posterior commissure coordinates of the active contacts and the total electrical energy delivered were calculated and correlated with clinical outcomes. Patient-specific tractographic analysis was performed to identify the modulated pathways in responders. RESULTS: Twelve women (70.6%) and 5 men (29.4%) with a median age of 48 yr (34-70 years) were included. Along the 5-year follow-up, 3 main clinical trajectories were observed according to symptom's improvement: great responders (≥80%), medium responders (≥50%-79%), and poor responders (<50%). Active contacts' coordinates and total electrical energy delivered showed no correlation with clinical outcomes. Brodmann area 10 medial was the most frequently stimulated area and the forceps minor, the most frequently modulated tract. CONCLUSION: SCG-DBS for TRD is clearly effective in some patients. Active contacts' coordinates were highly variable within the region and, like electrical parameters, did not seem to correlate with clinical outcomes. In the current series, Brodmann area 10 medial and the forceps minor were the most frequently targeted area and modulated pathway, respectively.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Aibar-Durán JÁ, Rodríguez Rodríguez R, de Diego Adeliño FJ, et al. Long-Term Results of Deep Brain Stimulation for Treatment-Resistant Depression: Outcome Analysis and Correlation With Lead Position and Electrical Parameters. Neurosurgery. 2022. PMID: 34982873. doi:10.1227/NEU.0000000000001739