椎动脉夹层动脉瘤破裂的临床与影像学危险因素:停滞征的意义
该研究回顾性分析2008年9月至2020年12月一家三级医院治疗的117例椎动脉夹层动脉瘤(VADA),破裂率为29.1%(34/117),停滞征出现率为39.3%(46/117)。多因素logistic回归显示梭形(OR 5.105)、表面不规则(OR 4.200)、小脑后下动脉(PICA)受累(OR 3.788)和停滞征(OR 3.317)与VADA破裂显著相关。
要点
- VADA破裂率为29.1%(34/117),停滞征出现率为39.3%(46/117)。
- 多因素分析中梭形、表面不规则、PICA受累和停滞征与破裂显著相关。
- 作者认为这些潜在危险因素出现于未破裂VADA时可考虑更积极治疗而非随访或药物治疗。
核心结论
- 梭形、表面不规则、PICA受累和停滞征可能是VADA破裂的独立危险因素。
- 作者认为未破裂VADA存在潜在危险因素时,可考虑更积极治疗而非随访或药物治疗。
研究设计与样本
- 回顾性分析2008年9月至2020年12月一家三级医院治疗的117例VADA的临床和影像学变量。
- 停滞征定义为血管造影静脉期病变内仍有对比剂残留。
- 采用单因素和多因素分析揭示破裂状态与VADA特征之间的关联。
主要发现
- VADA破裂率为29.1%(34/117),停滞征出现率为39.3%(46/117)。
- 多因素logistic回归显示梭形与破裂显著相关(OR 5.105,95%CI 1.591-16.383,p=0.006)。
- 表面不规则与破裂显著相关(OR 4.200,95%CI 1.412-12.495,p=0.010)。
- PICA受累与破裂显著相关(OR 3.788,95%CI 1.288-11.136,p=0.016)。
- 停滞征与破裂显著相关(OR 3.317,95%CI 1.131-9.732,p=0.029)。
关键数值与推荐
- 梭形:OR 5.105,95%CI 1.591-16.383,p=0.006。
- 表面不规则:OR 4.200,95%CI 1.412-12.495,p=0.010。
- PICA受累:OR 3.788,95%CI 1.288-11.136,p=0.016。
- 停滞征:OR 3.317,95%CI 1.131-9.732,p=0.029。
临床怎么用
- 作者认为未破裂VADA观察到潜在危险因素时,可考虑更积极治疗而非随访或药物治疗。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to investigate the clinical and radiological factors associated with the rupture of a vertebral artery dissecting aneurysm (VADA) and to evaluate whether the stagnation sign is a significant risk factor for rupture of VADA. METHODS: Clinical and radiological variables of 117 VADAs treated in a tertiary hospital from September 2008 to December 2020 were retrospectively reviewed. The stagnation sign is defined as the finding of contrast agent remaining in the lesion until the venous phase of angiography. Univariate and multivariate analyses were executed to reveal the associations between rupture status and VADA characteristics. RESULTS: The rate of ruptured VADAs was 29.1% (34 of 117) and the stagnation sign was observed in 39.3% (46 of 117). Fusiform shape (OR 5.105, 95% CI 1.591-16.383, p = 0.006), irregular surface (OR 4.200, 95% CI 1.412-12.495, p = 0.010), posterior inferior cerebellar artery (PICA) involvement (OR 3.788, 95% CI 1.288-11.136, p = 0.016), and the stagnation sign (OR = 3.317, 95% CI 1.131-9.732, p = 0.029) were significantly related to rupture of VADA in multivariate logistic regression analysis. CONCLUSIONS: This study showed that fusiform shape, irregular surface, PICA involvement, and the stagnation sign may be independent risk factors for the rupture of VADA. Therefore, when the potential risk factors are observed in unruptured VADA, more aggressive treatment rather than follow-up or medical therapy may be considered.
引用
- Lee HJ, Choi JH, Lee KS, et al. Clinical and radiological risk factors for rupture of vertebral artery dissecting aneurysm: significance of the stagnation sign. J Neurosurg. 2021. PMID: 34920434. doi:10.3171/2021.9.JNS211848
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。