文献速递神经肿瘤功能神经外科

清醒开颅条件下功能胶质瘤手术中纤维束示踪弥散信号模型的准确性比较

Comparison of Diffusion Signal Models for Fiber Tractography in Eloquent Glioma Surgery-Determination of Accuracy Under Awake Craniotomy Conditions.
PubMed 文献 · World Neurosurg · 2021-11-09

这项前瞻性研究纳入10例功能胶质瘤清醒开颅手术患者,比较概率Q球成像(QBI)、约束球面去卷积(CSD)与弥散张量成像(DTI)纤维束示踪与术中电刺激定位点的偏移。结果QBI平均最小偏移最低且与术中 mapping 结果相关性好,CSD与DTI间无显著差异。

要点

  • QBI纤维束示踪平均最小偏移低于CSD与DTI(P<0.001)。
  • CSD与DTI偏移无显著差异(P=0.105),仅复合SLF例外(P<0.001)。
  • QBI纤维束示踪适用于神经外科术前与术中应用。

核心结论

  • QBI较CSD与DTI纤维束示踪偏移更低且与术中电刺激结果相关性好,QBI与术中电刺激联合有助于在所述条件下最大程度保留神经功能。

研究设计与样本

  • 前瞻性研究纳入10例功能胶质瘤患者,在清醒开颅条件下手术,记录术中电刺激与神经心理定位的恶化点作为采集点,计算其与相应纤维束的偏移。
  • 比较概率Q球成像(QBI)、约束球面去卷积(CSD)与弥散张量成像(DTI)纤维束示踪对主要语言相关纤维束的定位准确性。

主要发现

  • 186个偏移值中46%距估计纤维束小于10 mm(CSD为36%,DTI为40%,QBI为60%)。
  • 仅10个偏移值距离大于30 mm(5%)。
  • QBI在SLF(7.7±7.9 mm)、下额枕束(12.7±8.3 mm)及下纵束/内侧纵束(17.7±6.7 mm)的平均最小偏移最低,分别显著优于CSD或DTI(P<0.001)。
  • CSD与DTI偏移无显著差异(P=0.105),仅复合SLF例外(P<0.001)。

临床怎么用

  • 原文结论认为QBI纤维束示踪在神经外科术前与术中应用可行。
  • 作者认为在所述条件下QBI纤维束示踪联合清醒开颅术中电刺激可考虑用于最大程度保留神经功能。
  • 作者认为将选定的高角分辨率纤维束示踪模型整合入神经导航系统似乎是胶质瘤手术中有前景的工具。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Fiber tractography (FT) has become an important noninvasive tool to ensure maximal safe tumor resection in eloquent glioma surgery. Intraoperatively applied FT is still predominantly based on diffusion tensor imaging (DTI). However, reconstruction schemes of high angular resolution diffusion imaging data for high-resolution FT (HRFT) are gaining increasing attention. The aim of this prospective study was to compare the accuracy of sophisticated HRFT models compared with DTI-FT. METHODS: Ten patients with eloquent gliomas underwent surgery under awake craniotomy conditions. The localization of acquisition points, representing deteriorations during intraoperative electrostimulation (IOM) and neuropsychological mapping, were documented. The offsets of acquisition points to the respective fiber bundle were calculated. Probabilistic Q-ball imaging (QBI) and constrained spherical deconvolution (CSD)-FT were compared with DTI-FT for the major language-associated fiber bundles (superior longitudinal fasciculus [SLF] II-IV, inferior fronto-occipital fasciculus, and inferior longitudinal fasciculus/medial longitudinal fasciculus). RESULTS: Among 186 offset values, 46% were located closer than 10 mm to the estimated fiber bundle (CSD, 36%; DTI, 40% and QBI, 60%). Moreover, only 10 offsets were further away than 30 mm (5%). Lowest mean minimum offsets (SLF, 7.7 ± 7.9 mm; inferior fronto-occipital fasciculus, 12.7 ± 8.3 mm; inferior longitudinal fasciculus/medial longitudinal fasciculus, 17.7 ± 6.7 mm) were found for QBI, indicating a significant advantage compared with CSD or DTI (P < 0.001), respectively. No significant differences were found between CSD-FT and DTI-FT offsets (P = 0.105), albeit for the compound SLF exclusively (P < 0.001). CONCLUSIONS: Comparing HRFT techniques QBI and CSD with DTI, QBI delivered significantly better results with lowest offsets and good correlation to IOM results. Besides, QBI-FT was feasible for neurosurgical preoperative and intraoperative applications. Our findings suggest that a combined approach of QBI-FT and IOM under awake craniotomy is considerable for best preservation of neurological function in the presented setting. Overall, the implementation of selected HRFT models into neuronavigation systems seems to be a promising tool in glioma surgery.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Becker D, Neher P, Jungk C, et al. Comparison of Diffusion Signal Models for Fiber Tractography in Eloquent Glioma Surgery-Determination of Accuracy Under Awake Craniotomy Conditions. World Neurosurg. 2021. PMID: 34767992. doi:10.1016/j.wneu.2021.11.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。