结构化照明显微镜定量分析足突、线粒体与基底膜
该研究利用结构化照明显微镜(SIM)分析临床常规制备的EMT和PAS染色肾切片,定量足突、线粒体和基底膜微结构。足突完整性经傅里叶变换功率谱评估,与蛋白尿负相关;线粒体损伤可量化,IgA肾病患者线粒体损伤预测活检后eGFR下降;PAS染色联合变异系数可量化膜性肾病I期基底膜细微改变。结论为SIM可从临床切片定量肾脏微结构。
要点
- SIM结合EMT染色可三维显示足突,功率谱评估的足突完整性与蛋白尿负相关。
- SIM可量化线粒体损伤,IgA肾病患者线粒体损伤预测活检后eGFR下降。
- PAS染色640nm激发联合变异系数可量化膜性肾病I期基底膜细微改变。
核心结论
- 肾脏微结构可通过临床常规制备的肾切片结合SIM进行定量分析。
研究设计与样本
- 研究分析EMT和PAS染色的肾切片,使用结构化照明显微镜(SIM)进行定量观察。
主要发现
- EMT染色显示足突三维结构,傅里叶变换功率谱中(1/4)2-(1/16)2同心方块包含正常足突周期性结构信息。
- 功率谱评估的足突完整性与蛋白尿负相关。
- EMT染色切片显示线粒体损伤小鼠和肾小管间质肾炎患者存在碎片化线粒体,傅里叶变换可量化相关线粒体损伤。
- IgA肾病患者线粒体损伤量化值预测肾活检后eGFR下降,但与活检时eGFR不相关。
- PAS染色切片经640nm激光激发,结合变异系数值可量化膜性肾病I期患者基底膜的细微变化。
临床怎么用
- SIM可利用临床常规EMT和PAS染色切片定量评估足突、线粒体和基底膜微结构,辅助局灶性病变评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Foot process effacement and mitochondrial fission associate with kidney disease pathogenesis. Electron microscopy is the gold-standard method for their visualization, but the observable area of electron microscopy is smaller than light microscopy. It is important to develop alternative ways to quantitatively evaluate these microstructural changes because the lesion site of renal diseases can be focal. METHODS: We analyzed elastica-Masson trichrome (EMT) and periodic acid-Schiff (PAS) stained kidney sections using structured illumination microscopy (SIM). RESULTS: EMT staining revealed three-dimensional (3D) structures of foot process, whereas ponceau xylidine acid fuchsin azophloxine solution induced fluorescence. Conversion of foot process images into their constituent frequencies by Fourier transform showed that the concentric square of (1/4)2-(1/16)2 in the power spectra (PS) included information for normal periodic structures of foot processes. Foot process integrity, assessed by PS, negatively correlated with proteinuria. EMT-stained sections revealed fragmented mitochondria in mice with mitochondrial injuries and patients with tubulointerstitial nephritis; Fourier transform quantified associated mitochondrial injury. Quantified mitochondrial damage in patients with immunoglobulin A (IgA) nephropathy predicted a decline in estimated glomerular filtration rate (eGFR) after kidney biopsy but did not correlate with eGFR at biopsy. PAS-stained sections, excited by a 640 nm laser, combined with the coefficient of variation values, quantified subtle changes in the basement membranes of patients with membranous nephropathy stage I. CONCLUSIONS: Kidney microstructures are quantified from sections prepared in clinical practice using SIM.
引用
- Matsumoto A, Matsui I, Katsuma Y, et al. Quantitative Analyses of Foot Processes, Mitochondria, and Basement Membranes by Structured Illumination Microscopy Using Elastica-Masson- and Periodic-Acid-Schiff-Stained Kidney Sections. Kidney Int Rep. 2021. PMID: 34307987. doi:10.1016/j.ekir.2021.04.021