尿液多重微珠检测成功用于评估狼疮肾炎活动性
该研究在46例20至73岁伴或不伴狼疮肾炎患者的341份晨尿样本中,比较ELISA与LUMINEX多重微珠法检测6种尿液生物标志物所构建的RAIL评分的可比性。结果显示LUMINEX可成功检测NGAL、KIM-1、MCP-1和脂联素4种标志物,基于这4种标志物的RAIL评分与ELISA法一致性良好(ICC=0.78,95%CI 0.78-0.82),且与基于全部6种标志物的RAIL评分高度相关(ICC=0.97,95%CI 0.96-0.98)。
要点
- LUMINEX可同时检测NGAL、KIM-1、MCP-1和脂联素4种尿液标志物。
- 基于4种标志物的RAIL评分与ELISA法一致性良好(ICC=0.78)。
- 4种标志物RAIL评分与6种标志物评分高度相关(ICC=0.97)。
核心结论
- LUMINEX平台可便捷地同时检测4种RAIL生物标志物,仅用这4种标志物的RAIL评分可能足以准确反映狼疮肾炎活动性。
研究设计与样本
- 研究纳入46例20至73岁伴或不伴狼疮肾炎患者,采集341份晨尿样本,分别用ELISA和LUMINEX多重微珠法检测生物标志物并计算RAIL评分,采用组内相关系数、Bland-Altman和回归评估一致性。
主要发现
- LUMINEX成功检测NGAL、KIM-1、MCP-1和脂联素,但未能成功检测铜蓝蛋白和血红素结合蛋白。
- 基于4种标志物的RAIL评分在两种检测方法间一致性良好(ICC=0.78,95%CI 0.78-0.82)。
- 基于4种标志物的RAIL评分与基于全部6种标志物的RAIL评分高度相关(ICC=0.97,95%CI 0.96-0.98)。
关键数值与推荐
- RAIL评分基于NGAL、KIM-1、MCP-1、脂联素、血红素结合蛋白和铜蓝蛋白6种尿液生物标志物构建。
- LUMINEX法仅对NGAL、KIM-1、MCP-1和脂联素检测成功。
- 4种标志物RAIL评分与ELISA法ICC=0.78(95%CI 0.78-0.82)。
- 4种标志物RAIL评分与6种标志物RAIL评分ICC=0.97(95%CI 0.96-0.98)。
临床怎么用
- 临床可采用LUMINEX平台同时检测4种尿液标志物(NGAL、KIM-1、MCP-1、脂联素)并计算RAIL评分以评估狼疮肾炎活动性。
- 基于4种标志物的RAIL评分与基于6种标志物的评分高度一致,可能简化检测流程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Lupus nephritis (LN) confers a poor prognosis, mainly from lack of effective laboratory tests to diagnose and to evaluate therapies. We have previously shown that a set of 6 urinary biomarkers (NGAL, KIM-1, MCP-1, adiponectin, hemopexin, and ceruloplasmin) are highly sensitive and specific to identify adult and pediatric patients with active LN using renal biopsy as reference standard. Using these combinatorial urinary biomarkers, the Renal Activity Score for Lupus (RAIL) score was established, with biomarkers measured by enzyme-linked immunosorbent assay (ELISA). To enhance clinical utility of the biomarkers and RAIL, we tested the performance of RAIL with biomarkers measured by ELISA to that of biomarkers measured by the bead multiplex method, hypothesizing that the multiplex bead method would be comparable. METHODS: Spot urine samples (n = 341) of 46 patients aged 20 to 73 years with or without LN were used. Samples were assayed both by ELISA and multiplex using LUMINEX. RAIL scores and biomarker quantities were assessed for agreement with intraassay correlation coefficients and compared using Bland-Altman and regression. RESULTS: Biomarker measurement by LUMINEX was successful for NGAL, KIM-1, MCP-1, and adiponectin, but not for ceruloplasmin and hemopexin. There was good agreement of the RAIL obtained from these 4 biomarkers, irrespective of assay method (intraclass correlation coefficient [ICC] = 0.78, 95% confidence interval [CI] = 0.78-0.82). The RAIL scores from 4 biomarkers further correlated with those when considering all 6 biomarkers (ICC = 0.97, 95% CI = 0.96-0.98). CONCLUSION: The LUMINEX platform allows for the convenient and simultaneous measurement of 4 RAIL biomarkers. RAIL scores considering only these 4 biomarkers may be sufficient to accurately capture LN activity.
引用
- Cody EM, Bennett MR, Gulati G, et al. Successful Urine Multiplex Bead Assay to Measure Lupus Nephritis Activity. Kidney Int Rep. 2021. PMID: 34307989. doi:10.1016/j.ekir.2021.04.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。