超滤率与老年初始血液透析患者心房颤动发病的相关性
结果发现3177例发生心房颤动,超滤率>13 mL/h/kg相比≤13 mL/h/kg的调整HR为1.19(95%CI 1.07-1.30),且呈近似线性剂量反应关系,风险自约6 mL/h/kg开始,≥9 mL/h/kg后风险增幅趋平但仍升高。
要点
- 超滤率>13 mL/h/kg与心房颤动风险增加独立相关(调整HR 1.19)。
- 超滤率与心房颤动风险呈近似线性剂量反应,风险自约6 mL/h/kg开始上升。
- 较低阈值(>10或>8 mL/h/kg)分析结果与主分析一致。
核心结论
- 在老年初始血液透析患者中,较高的超滤率与较高的心房颤动发病率相关。
研究设计与样本
- 采用扩展Cox模型,以时间依赖性超滤率为暴露,计算调整风险比(HR)及95%置信区间(CI)。
主要发现
- 中位随访期间,3177例发生心房颤动。
- 超滤率>13 mL/h/kg相比≤13 mL/h/kg,心房颤动的调整HR为1.19(95%CI 1.07-1.30)。
- 使用较低阈值(≤10 vs >10 mL/h/kg;≤8 vs >8 mL/h/kg)分析结果相似。
- 立方样条分析(每1 mL/h/kg)显示近似线性剂量反应关系,风险自约6 mL/h/kg开始,≥9 mL/h/kg后风险增幅趋平但仍升高。
临床怎么用
- 在老年初始血液透析患者中,处方超滤率>13 mL/h/kg时需警惕心房颤动风险增加。
- 可考虑将超滤率控制在较低水平以降低心房颤动风险,但需权衡容量控制。
局限性
- 本研究为观察性研究,不能确立因果关系。
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Higher ultrafiltration (UF) rates are associated with numerous adverse cardiovascular outcomes among individuals receiving maintenance hemodialysis. We undertook this study to investigate the association of UF rate and incident atrial fibrillation in a large, nationally representative US cohort of incident, older hemodialysis patients. METHODS: We used the US Renal Data System linked to the records of a large dialysis provider to identify individuals ≥67 years of age initiating hemodialysis between January 2006 and December 2011. We applied an extended Cox model as a function of a time-varying exposure to compute adjusted hazard ratios (HRs) and 95% confidence intervals (CIs) for the association of delivered UF rate and incident atrial fibrillation. RESULTS: Among the 15 414 individuals included in the study, 3177 developed atrial fibrillation. In fully adjusted models, a UF rate >13 mL/h/kg (versus ≤13 mL/h/kg) was associated with a higher hazard of incident atrial fibrillation [adjusted HR 1.19 (95% CI 1.07-1.30)]. Analyses using lower UF rate thresholds (≤10 versus >10 mL/h/kg and ≤8 versus >8 mL/h/kg, separately) yielded similar results. Analyses specifying the UF rate as a cubic spline (per 1 mL/h/kg) confirmed an approximately linear dose-response relationship between the UF rate and the risk of incident atrial fibrillation: risk began at UF rates of ~6 mL/h/kg and the magnitude of this risk flattened, but remained elevated, at rates ≥9 mL/h/kg. CONCLUSION: In this observational study of older individuals initiating hemodialysis, higher UF rates were associated with higher incidences of atrial fibrillation.
引用
- Flythe JE, Liu S, Montez-Rath ME, et al. Ultrafiltration rate and incident atrial fibrillation among older individuals initiating hemodialysis. Nephrol Dial Transplant. 2021. PMID: 33561218. doi:10.1093/ndt/gfaa332
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。