文献速递慢性肾脏病遗传性与小管间质肾病

临床前MRI中全自动肾脏总体积测量方法的验证与资源开放

Automated total kidney volume measurements in pre-clinical magnetic resonance imaging for resourcing imaging data, annotations, and source code.
PubMed 文献 · Kidney Int · 2020-08-20

本研究验证了一种用于临床前啮齿类动物试验的全自动肾脏总体积测量方法,该方法快速、准确、可重复,并向研究社区提供相关资源。自动方法无需用户输入(仅需最终视觉质量控制),其与手动分割的相似性指标与观察者间和观察者内比较相当,可安全用于涉及啮齿类动物肾脏分割的纵向临床前试验。

要点

  • 全自动肾脏总体积测量无需用户输入,仅需最终视觉质量控制。
  • 自动方法与手动分割的相似性指标与观察者间和观察者内比较相当。
  • 该方法可安全用于涉及啮齿类动物肾脏分割的纵向临床前T2加权MRI试验。

核心结论

  • 全自动肾脏总体积测量方法快速、准确、可重复,可安全用于纵向临床前试验。

研究设计与样本

  • 使用150张来自多种小鼠模型的轴位MRI手动分割图像训练和验证自动算法。

主要发现

  • 自动方法与手动分割的相似性指标与观察者间和观察者内比较相当。
  • 自动方法除最终视觉质量控制外无需用户输入。

临床怎么用

  • 可在涉及啮齿类动物肾脏分割的纵向临床前T2加权MRI试验中使用全自动方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The objective of this study was to validate a fully automated total kidney volume measurement method for pre-clinical rodent trials that is fast, accurate, reproducible, and to provide these resources to the research community. Rodent studies that involve imaging are crucial for monitoring treatment efficacy in diseases such as polycystic kidney disease. Previous studies utilize manual or semi-automated segmentations, which are time consuming and potentially biased. To develop our automated system, a total of 150 axial magnetic resonance images (MRI) from a variety of mouse models were manually segmented and used to train/validate an automated algorithm. To test the longitudinal application of the model, four mutant and four wild-type mice were imaged sequentially over three to twelve weeks via MRI. Segmentations of the kidneys (excluding the renal pelvis) were generated by the automated method and two different readers, with one reader repeating the measurements. Similarity metrics and longitudinal analysis were calculated to assess the performance of the automated compared to the manual methods. The automated approach required no user input, besides a final visual quality control step. Similarity metrics of the automated method versus the manual segmentations were on par with inter- and intra-reader comparisons. Thus, our fully automated approach described here can be safely used in longitudinal, pre-clinical trials that involve the segmentation of rodent kidneys in T2-weighted MRIs.

来源:Kidney Int,查看原文。版权归原作者所有。

引用

  1. Edwards ME, Periyanan S, Anaam D, et al. Automated total kidney volume measurements in pre-clinical magnetic resonance imaging for resourcing imaging data, annotations, and source code. Kidney Int. 2020. PMID: 32828755. doi:10.1016/j.kint.2020.07.040