基于电导率清除率计算Kt/V并减少透析后血尿素氮测量的新方法
该研究比较了常规基于尿素减少率(URR)计算Kt/V的方法与基于电导率清除率(Kecn)和校准分布容积(Vcal)且无需频繁测量透析后血尿素氮(SUN)的新方法。在1093例维持性血液透析患者中,两种方法得到的Kt/V患者水平中位数差异百分比分别为-0.63%±7.7%和-0.75%±8.4%,标准化蛋白氮显现率相当。新方法可减少透析后SUN测量并避免采样误差。
要点
- 基于Kecn的新Kt/V计算方法与常规URR法结果 comparable,差异小。
- 新方法减少透析后SUN测量需求,潜在避免采样和测量误差。
- 标准化蛋白氮显现率在两种方法间相当。
核心结论
- 基于Kecn且减少透析后SUN测量的新Kt/V计算方法,与常规URR法提供可比的诊断数据。
研究设计与样本
- 比较两种诊断测试的研究,纳入1093例维持性血液透析至少2年的普遍患者。
主要发现
- 基线期、第1期和第2期常规法患者水平中位单室Kt/V分别为1.62±0.24、1.66±0.24和1.67±0.24。
- 第1期和第2期基于Kecn的患者水平中位Kt/V分别为1.64±0.24和1.65±0.24。
- 患者水平中位Kt/V的百分比差异(电导率法减常规URR法)在第1期和第2期分别为-0.63%±7.7%和-0.75%±8.4%。
- 标准化蛋白氮显现率在两种方法间相当。
临床怎么用
- 新方法可减少透析后SUN测量频率,并可能避免与透析后血样采集和测量相关的误差。
局限性
- 数据收集历时2年。
- 研究仅限于每周透析3次的中心血液透析患者。
- 透析治疗中断时未调整透析时长。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RATIONALE & OBJECTIVES: Conventional monitoring of hemodialysis dose is implemented using urea kinetic modeling based on single-pool Kt/V, which requires both pre- and postdialysis serum urea nitrogen (SUN) measurements. We compared this conventional approach to one in which Kt/V is calculated using conductivity clearance, thereby reducing the need for regular postdialysis SUN measurements. STUDY DESIGN: Comparative study of 2 diagnostic tests. SETTING & PARTICIPANTS: Prevalent patients receiving maintenance hemodialysis for at least 2 years for whom both urea reduction ratio (URR) and average conductivity clearance (Kecn) were measured. TESTS COMPARED: During the initial 8 months (baseline interval), average Kecn and URR were used to calculate a median patient-specific, modeled, calibration solute distribution volume (Vcal). During months 9 to 16 (period 1) and 17 to 24 (period 2), Kt/V was conventionally computed using URR and also by a new method using Vcal and Kecn without postdialysis SUN values. We examined the percentage error between these 2 methods of calculating Kt/V. OUTCOMES: Concordance between the 2 methods of calculating Kt/V. RESULTS: Among 1,093 patients, mean individual-level median single-pool Kt/V values derived using the conventional method during the baseline interval, period 1, and period 2 were 1.62±0.24 (SD), 1.66±0.24, and 1.67±0.24, respectively. During periods 1 and 2, patient-level median Kt/V values derived using Kecn were 1.64±0.24 and 1.65±0.24, respectively. Percent differences between patient-level median values of Kt/V (conductivity minus conventional URR methods) were-0.63%±7.7% and-0.75%±8.4% for periods 1 and 2. Normalized protein nitrogen appearance were comparable between the 2 methods. LIMITATIONS: Data were collected over 2 years. Study was limited to in-center hemodialysis patients dialyzed 3 times per week. Dialysis session length was not adjusted for treatment interruptions. CONCLUSIONS: A new method of calculating Kt/V based on Kecn that requires fewer postdialysis SUN measurements provided diagnostic data comparable to those from conventional use of URR and has the potential to avoid errors related to postdialysis blood sampling and measurement.
引用
- Raimann JG, Ye X, Kotanko P, et al. Routine Kt/V and Normalized Protein Nitrogen Appearance Rate Determined From Conductivity Access Clearance With Infrequent Postdialysis Serum Urea Nitrogen Measurements. Am J Kidney Dis. 2020. PMID: 32220509. doi:10.1053/j.ajkd.2019.12.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。