纽扣孔穿刺法增加动静脉内瘘感染风险:NHSN数据
基于美国国家医疗安全网络2013-2014年门诊透析中心监测数据,比较纽扣孔穿刺(BHC)与绳梯穿刺(RLC)动静脉内瘘的感染风险。BHC与通路相关血流感染(aRR 2.6,95%CI 2.4-2.8)和局部通路部位感染(aRR 1.5,95%CI 1.4-1.6)风险显著升高相关,但与静脉抗菌药物启用风险无关。
要点
- BHC与通路相关血流感染风险较RLC升高约2.6倍
- BHC与局部通路部位感染风险较RLC升高约1.5倍
- BHC通路相关血流感染中金黄色葡萄球菌占52%
核心结论
- 在门诊血液透析患者中,BHC与血管通路相关感染风险高于RLC。
- 透析中心决定是否使用BHC时应考虑其较高的感染风险。
研究设计与样本
- 描述性感染分析及回顾性观察性队列研究,使用美国国家医疗安全网络(NHSN)监测数据。
- 对象为在美国门诊透析中心接受血液透析的患者。
主要发现
- 2013-2014年BHC患者中发生2466例通路相关血流感染、3169例局部通路部位感染和13726次静脉抗菌药物启用。
- BHC通路相关血流感染中最常见病原体为金黄色葡萄球菌,占52%。
- BHC通路相关血流感染中住院频繁,占37%。
- 2014年NHSN报告的所有动静脉内瘘患者月中9%(n=271980)与BHC相关。
- 调整设施特征和实践后,BHC与通路相关血流感染(aRR 2.6;95%CI 2.4-2.8)和局部通路部位感染(aRR 1.5;95%CI 1.4-1.6)风险显著升高相关,但与静脉抗菌药物启用风险增加无关。
临床怎么用
- 在门诊透析中心选择动静脉内瘘穿刺方式时,应权衡BHC较高的感染风险。
局限性
- 设施实践数据为自我报告且非患者特异性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RATIONALE & OBJECTIVE: Compared with conventional (rope-ladder cannulation [RLC]) methods, use of buttonhole cannulation (BHC) to access arteriovenous fistulas (AVFs) may be associated with increased risk for bloodstream infection and other vascular access-related infection. We used national surveillance data to evaluate the infection burden and risk among in-center hemodialysis patients with AVFs using BHC. STUDY DESIGN: Descriptive analysis of infections and related events and retrospective observational cohort study using National Healthcare Safety Network (NHSN) surveillance data. SETTING & PARTICIPANTS: US patients receiving hemodialysis treated in outpatient dialysis centers. PREDICTORS: AVF cannulation methods, dialysis facility characteristics, and infection control practices. OUTCOMES: Access-related bloodstream infection; local access-site infection; intravenous (IV) antimicrobial start. ANALYTIC APPROACH: Description of frequency and rate of infections; adjusted relative risk (aRR) for infection with BHC versus RLC estimated using Poisson regression. RESULTS: During 2013 to 2014, there were 2,466 access-related bloodstream infections, 3,169 local access-site infections, and 13,726 IV antimicrobial starts among patients accessed using BHC. Staphylococcus aureus was the most common pathogen, present in half (52%) of the BHC access-related bloodstream infections. Hospitalization was frequent among BHC access-related bloodstream infections (37%). In 2014, 9% (n=271,980) of all AVF patient-months reported to NHSN were associated with BHC. After adjusting for facility characteristics and practices, BHC was associated with significantly higher risk for access-related bloodstream infection (aRR, 2.6; 95% CI, 2.4-2.8) and local access-site infection (aRR, 1.5; 95% CI, 1.4-1.6) than RLC, but was not associated with increased risk for IV antimicrobial start. LIMITATIONS: Data for facility practices were self-reported and not patient specific. CONCLUSIONS: BHC was associated with higher risk for vascular access-related infection than RLC among in-center hemodialysis patients. Decisions regarding the use of BHC in dialysis centers should take into account the higher risk for infection. Studies are needed to evaluate infection control measures that may reduce infections related to BHC.
引用
- Lyman M, Nguyen DB, Shugart A, et al. Risk of Vascular Access Infection Associated With Buttonhole Cannulation of Fistulas: Data From the National Healthcare Safety Network. Am J Kidney Dis. 2020. PMID: 32151430. doi:10.1053/j.ajkd.2019.11.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。