文献速递肾移植

功能磁共振联合病理评估移植肾间质纤维化

Combination of Functional Magnetic Resonance Imaging and Histopathologic Analysis to Evaluate Interstitial Fibrosis in Kidney Allografts.
PubMed 文献 · Clin J Am Soc Nephrol · 2019-08-15

该前瞻性研究纳入103例因病因行活检的肾移植受者和20例活检证实的正常受试者,评估功能MRI对移植肾间质纤维化的诊断价值。结果显示表观扩散系数、动脉自旋标记等指标与间质纤维化程度显著相关,鉴别≤50%与>50%间质纤维化的曲线下面积达0.85~0.94。

要点

  • 功能MRI指标与移植肾间质纤维化程度显著相关。
  • 动脉自旋标记鉴别间质纤维化的AUC最高达0.94。
  • 功能MRI有望无创评估移植肾间质纤维化。

核心结论

  • 功能MRI测量值与移植肾间质纤维化强相关,鉴别≤50%与>50%间质纤维化性能良好至优秀。

研究设计与样本

  • 前瞻性单中心队列,纳入103例因病因行活检的肾移植受者和20例活检证实的正常受试者,行功能MRI及组织形态学分析。

主要发现

  • 主要病理诊断为排斥反应(32%)和肾小球肾炎(31%)。
  • 表观扩散系数与间质纤维化相关(ρ=-0.77;P<0.001)。
  • 动脉自旋标记降低伴随管周毛细血管密度减少(r=0.77;P<0.001)。
  • 血氧水平依赖成像显示皮质缺氧随间质纤维化增加(ρ=0.61;P<0.001)。

关键数值与推荐

  • 表观扩散系数鉴别≤25% vs >25%和≤50% vs >50%间质纤维化的AUC分别为0.87(95%CI 0.79~0.93)和0.88(95%CI 0.80~0.93)。
  • 动脉自旋标记对应AUC分别为0.92(95%CI 0.85~0.97)和0.94(95%CI 0.87~0.98)。
  • 灌注分数对应AUC分别为0.81(95%CI 0.72~0.88)和0.86(95%CI 0.78~0.92)。
  • 血氧水平依赖成像对应AUC分别为0.79(95%CI 0.69~0.87)和0.85(95%CI 0.76~0.92)。

临床怎么用

  • 功能MRI可作为无创评估移植肾间质纤维化的潜在工具,辅助临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Recent developments indicated that functional magnetic resonance imaging (MRI) could potentially provide noninvasive assessment of kidney interstitial fibrosis in patients with kidney diseases, but direct evidence from histopathology is scarce. We aimed to explore the diagnostic utilities of functional MRI for the evaluation of kidney allograft interstitial fibrosis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We prospectively examined 103 kidney transplant recipients who underwent for-cause biopsies and 20 biopsy-proven normal subjects with functional MRI. Histomorphometric analyses of interstitial fibrosis and peritubular capillary densities were performed on digitally scanned Masson's trichrome- and CD34-stained slides, respectively. The performances of functional MRI to discriminate interstitial fibrosis were assessed by calculating the area under the curve using receiver-operating characteristic curve. RESULTS: Main pathologic findings in this single-center cohort were representative of common diagnostic entities in the kidney allografts, with rejection (32%) and glomerulonephritides (31%) accounting for the majority of diagnoses. Apparent diffusion coefficient from diffusion-weighted imaging correlated with interstitial fibrosis (ρ=-0.77; P<0.001). Additionally, decreased arterial spin labelings were accompanied by peritubular capillary density reductions (r=0.77; P<0.001). Blood oxygen level-dependent (BOLD) imaging demonstrated cortical hypoxia with increasing interstitial fibrosis (ρ=0.61; P<0.001). The area under the curve for the discrimination of ≤25% versus >25% interstitial fibrosis and ≤50% versus >50% interstitial fibrosis were 0.87 (95% confidence interval [95% CI], 0.79 to 0.93) and 0.88 (95% CI, 0.80 to 0.93) by apparent diffusion coefficient, 0.92 (95% CI, 0.85 to 0.97) and 0.94 (95% CI, 0.87 to 0.98) by arterial spin labeling, 0.81 (95% CI, 0.72 to 0.88) and 0.86 (95% CI, 0.78 to 0.92) by perfusion fraction, 0.79 (95% CI, 0.69 to 0.87) and 0.85 (95% CI, 0.76 to 0.92) by BOLD imaging, respectively. CONCLUSIONS: Functional MRI measurements were strongly correlated with kidney allograft interstitial fibrosis. The performances of functional MRI for discriminating ≤50% versus >50% interstitial fibrosis were good to excellent.

来源:Clin J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Wang W, Yu Y, Wen J, et al. Combination of Functional Magnetic Resonance Imaging and Histopathologic Analysis to Evaluate Interstitial Fibrosis in Kidney Allografts. Clin J Am Soc Nephrol. 2019. PMID: 31416890. doi:10.2215/CJN.00020119

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。