文献速递慢性肾脏病

中国人群肾小球滤过率更准确估算方程的开发与验证

Development and validation of a more accurate estimating equation for glomerular filtration rate in a Chinese population.
PubMed 文献 · Kidney Int · 2019-01-29

该研究基于中国3家医院8571名接受直接测量GFR的成人,开发并验证了新的Xiangya方程。新方程在内部验证中P30达84.33%,外部验证中P30最高,优于其他12个基于肌酐的eGFR方程,可替代现有方程用于中国人群。

要点

  • Xiangya方程在中国成人中外部验证P30最高,优于其他12个eGFR方程。
  • 新方程在开发集和内部验证集P30分别为79.21%和84.33%。
  • 新方程偏差低,内部验证平均差-1.85 ml/min per 1.73 m2。

核心结论

  • 新Xiangya方程在中国成人中提供更准确的GFR估算,可替代现有eGFR方程。

研究设计与样本

  • 多中心研究,纳入8571名接受直接测量GFR的成人,来自中国3家代表性医院。
  • 开发集来自湘雅三医院1730人,内部验证集1042人,外部验证集来自其他医院5799人。

主要发现

  • 开发集和内部验证集P30分别为79.21%和84.33%。
  • 开发集和内部验证集平均差分别为-1.97和-1.85 ml/min per 1.73 m2。
  • 开发集和内部验证集差值四分位距分别为21.13和18.88 ml/min per 1.73 m2。
  • 外部验证中Xiangya方程P30最高,其他12个方程P30均≤75%。

临床怎么用

  • 在中国成人中可考虑使用Xiangya方程替代现有eGFR方程进行GFR估算。

局限性

  • 研究排除了服用影响肌酐小管分泌药物、透析、肾移植及肌酐>700 μmol/l的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Previously published equations to estimate glomerular filtration rate (GFR) have limited accuracy in Asian populations. We aimed to develop and validate a more accurate equation for estimated GFR (eGFR) in the Chinese population, using data from 8571 adults who were referred for direct measurement of GFR by renal dynamic imaging (mGFR) at 3 representative hospitals in China. Patients from the Third Xiangya Hospital were included in our development (n=1730) and internal validation sets (n=1042) and patients from the other hospitals comprised the external validation set (n=5799). We excluded patients who were prescribed medications known to influence the tubular secretion of creatinine, patients on dialysis, kidney transplant recipients, and patients with missing creatinine values or with creatinine >700 μmol/l. We derived a novel eGFR equation by linear regression analysis and compared the performance to 12 creatinine-based eGFR equations, including previously published equations for use in Chinese or Asian populations. In the development and internal validation sets, the novel Xiangya equation had high accuracy (accuracy within 30% [P30], 79.21% and 84.33%, respectively), low bias (mean difference between mGFR and eGFR, -1.97 and -1.85 ml/min per 1.73 m2, respectively), and high precision (interquartile range of the differences, 21.13 and 18.88 ml/min per 1.73 m2, respectively). In external validation, the Xiangya equation had the highest P30 among all eGFR equations, with P30 ≤ 75% for the other 12 equations. This novel equation provides more accurate GFR estimates in Chinese adults and could replace existing eGFR equations for use in the Chinese population.

来源:Kidney Int,查看原文。版权归原作者所有。

引用

  1. Li DY, Yin WJ, Yi YH, et al. Development and validation of a more accurate estimating equation for glomerular filtration rate in a Chinese population. Kidney Int. 2019. PMID: 30709663. doi:10.1016/j.kint.2018.10.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。