PubMed 文献 · Clin J Am Soc Nephrol · 2019-02-05

该研究基于DOPPS第四期(2009-2012)数据,分析12国273家透析中心10250例患者,评估血透中心容量与透析中低血压管理实践与患者结局的关联。结果显示,定期评估干体重的方案与较低全因和心血管死亡相关,而钠建模/ profiling与较高死亡和心血管事件相关。

要点

  • 定期评估干体重的方案与较低全因和心血管死亡相关。
  • 常规立位血压评估干体重与较低住院和心血管事件相关。
  • 钠建模/ profiling与较高全因死亡、心血管死亡和事件相关。

核心结论

  • 血透中心容量与透析中低血压管理实践与患者结局相关。

研究设计与样本

  • 分析DOPPS第四期(2009-2012)数据,纳入12国273家透析中心10250例患者。
  • 采用Cox回归模型(共享 frailty)评估中心实践与结局的关联,并调整多项混杂因素。

主要发现

  • 多数患者有定期评估干体重的方案与较低全因死亡(HR 0.78;99% CI 0.64-0.94)和心血管死亡(HR 0.72;99% CI 0.55-0.95)相关。
  • 常规立位血压评估干体重与较低全因住院(HR 0.86;99% CI 0.77-0.97)和心血管事件(HR 0.85;99% CI 0.73-0.98)相关。
  • 常规使用较低透析液温度以限制或预防透析中低血压与较低心血管死亡(HR 0.76;99% CI 0.58-0.98)相关。
  • 常规使用在线容量指标评估干体重与较高全因住院(HR 1.19;99% CI 1.02-1.38)相关。
  • 常规使用钠建模/ profiling以限制或预防透析中低血压与较高全因死亡(HR 1.36;99% CI 1.14-1.63)、心血管死亡(HR 1.34;99% CI 1.04-1.73)和心血管事件(HR 1.21;99% CI 1.03-1.43)相关。

临床怎么用

  • 可考虑制定定期评估干体重的方案,并常规采用立位血压评估干体重。
  • 对透析中低血压管理,需谨慎使用钠建模/ profiling,并关注在线容量指标使用的潜在风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Fluid overload and intradialytic hypotension are associated with cardiovascular events and mortality in patients on hemodialysis. We investigated associations between hemodialysis facility practices related to fluid volume and intradialytic hypotension and patient outcomes. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Data were analyzed from 10,250 patients in 273 facilities across 12 countries, from phase 4 of the Dialysis Outcomes and Practice Patterns Study (DOPPS; 2009-2012). Cox regression models (shared frailty) were used to estimate associations between facility practices reported by medical directors in response to the DOPPS Medical Directors Survey and all-cause and cardiovascular mortality and hospitalization, and cardiovascular events, adjusting for country, age, sex, dialysis vintage, predialysis systolic BP, cardiovascular comorbidities, diabetes, body mass index, smoking, residual kidney function, dialysis adequacy, and vascular access type. RESULTS: Of ten facility practices tested (chosen a priori), having a protocol that specifies how often to assess dry weight in most patients was associated with lower all-cause (hazard ratio [HR], 0.78; 99% confidence interval [99% CI], 0.64 to 0.94) and cardiovascular mortality (HR, 0.72; 99% CI, 0.55 to 0.95). Routine orthostatic BP measurement to assess dry weight was associated with lower all-cause hospitalization (HR, 0.86; 99% CI, 0.77 to 0.97) and cardiovascular events (HR, 0.85; 99% CI, 0.73 to 0.98). Routine use of lower dialysate temperature to limit or prevent intradialytic hypotension was associated with lower cardiovascular mortality (HR, 0.76; 99% CI, 0.58 to 0.98). Routine use of an online volume indicator to assess dry weight was associated with higher all-cause hospitalization (HR, 1.19; 99% CI, 1.02 to 1.38). Routine use of sodium modeling/profiling to limit or prevent intradialytic hypotension was associated with higher all-cause mortality (HR, 1.36; 99% CI, 1.14 to 1.63), cardiovascular mortality (HR, 1.34; 99% CI, 1.04 to 1.73), and cardiovascular events (HR, 1.21; 99% CI, 1.03 to 1.43). CONCLUSIONS: Hemodialysis facility practices relating to the management of fluid volume and intradialytic hypotension are associated with patient outcomes.

来源:Clin J Am Soc Nephrol,查看原文。版权归原作者所有。