血液透析与血液透析滤过中中分子透析内动力学
研究利用β2-微球蛋白、肌红蛋白和补体因子D的透析内血浆浓度及透析器总清除率,在35例患者中估算双室模型参数。结果显示肌红蛋白和补体因子D的室间清除率及中央室容积小于β2-微球蛋白(P<0.001),且中央室容积与透析器总清除率相关,提示大分子中分子需采用依赖清除率的小中央室模型描述。
要点
- 肌红蛋白和补体因子D的室间清除率及中央室容积小于β2-微球蛋白。
- 中央室容积和室间清除率与透析器总清除率相关(P<0.001)。
- 总分布容积与透析器总清除率无关(P=0.083)。
核心结论
- 双室动力学模型仅当中央室容积小且依赖透析器总清除率时,才能描述分子量大于β2-微球蛋白的中分子透析内动力学。
研究设计与样本
- 探索性分析,纳入两项临床试验中接受中截留透析器血液透析及高通量透析器血液透析或血液透析滤过的患者。
- 共35例患者,获得345组动力学参数。
- 利用β2-微球蛋白(11.8 kD)、肌红蛋白(16.7 kD)和补体因子D(24.4 kD)的透析内血浆浓度及透析器总清除率估算双室模型参数。
主要发现
- 肌红蛋白和补体因子D的室间清除率与中央室容积均小于β2-微球蛋白(P < 0.001)。
- 无论何种中分子,室间清除率和中央室容积均与透析器总清除率相关(P < 0.001)。
- 总分布容积与透析器总清除率无关(P = 0.083)。
临床怎么用
- 解读中分子清除数据时需考虑中央室容积随透析器清除率变化,不宜直接套用β2-微球蛋白的固定参数模型。
局限性
- 为探索性分析,合并了不同透析器的动力学参数。
- 样本量有限(35例患者)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The kinetics of β2-microglobulin during hemodialysis and hemodiafiltration is well described by a two-compartment model where clearance by the dialyzer is from a central compartment volume that approximates plasma volume and a total distribution volume that approximates extracellular fluid volume. The kinetics of middle molecules with molecular weights larger than β2-microglobulin have not been extensively studied. METHODS: Intradialytic plasma concentrations and overall dialyzer clearances of β2-microglobulin (11.8 kD), myoglobin (16.7 kD) and complement factor D (24.4 kD) were used to estimate three kinetic parameters from a two-compartment model, namely intercompartmental clearance, central compartment volume and total distribution volume, in hemodialysis patients; these data were collected during two clinical trials of medium cut-off dialyzers (with extended middle molecule removal) during hemodialysis and high-flux dialyzers during hemodialysis and hemodiafiltration. In the current exploratory analyses, the kinetic parameters from all dialyzers were combined. Overall dialyzer clearance was evaluated by total mass removed in the dialysate. RESULTS: In total, 345 sets of kinetic parameters from 35 patients were determined. Intercompartmental clearance and central compartment volume for myoglobin and complement factor D were smaller (P < 0.001) than those for β2-microglobulin. Independent of middle molecule, intercompartmental clearance and central compartment volume were associated with overall dialyzer clearance (P < 0.001), but total distribution volume was not (P = 0.083). CONCLUSIONS: A two-compartment kinetic model can only describe intradialytic kinetics of middle molecules with molecular weights larger than β2-microglobulin if the central compartment is small and dependent on overall dialyzer clearance.
引用
- Leypoldt JK, Storr M, Agar BU, et al. Intradialytic kinetics of middle molecules during hemodialysis and hemodiafiltration. Nephrol Dial Transplant. 2019. PMID: 30307514. doi:10.1093/ndt/gfy304
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。