文献速递肾移植

不可控心死亡供肾移植功能预测模型:脉冲式肾脏保存机FRR截断值的有效性

The development of a predictive model of graft function in uncontrolled donors after circulatory death: validity of a pulsatile renal preservation machine cut-off value for kidney acceptance.
PubMed 文献 · Nephrol Dial Transplant · 2019-01-01

本研究纳入2004至2016年单中心194例不可控心死亡供肾移植受者,分析终末肾阻力(FRR)对移植后6个月GFR≥30 mL/min的预测价值。结果显示供者年龄≥60岁且FRR≥0.3 mmHg/mL/min可预测低免疫风险受者移植后6个月肾功能不良,ROC曲线预测准确度达0.968。

要点

  • 供者年龄≥60岁者FRR均值0.27±0.11 mmHg/mL/min,显著高于<60岁者的0.22±0.09(P=0.042)。
  • 供者≥60岁组中,GFR<30组FRR为0.37±0.08,GFR≥30组为0.18±0.06 mmHg/mL/min(P<0.001)。
  • FRR≥0.3 mmHg/mL/min预测6个月GFR<30的灵敏度67%、特异度100%、阳性预测值83%、阴性预测值92%。

核心结论

  • 不可控心死亡供者中,供者年龄≥60岁联合FRR≥0.3 mmHg/mL/min可预测低免疫风险受者移植后6个月肾功能不良。

研究设计与样本

  • 单中心回顾性研究,纳入2004至2016年本院所有不可控心死亡供肾移植,共194例受者。
  • 终点为移植后6个月肾小球滤过率(GFR)≥30 mL/min。

主要发现

  • 供者≥60岁者FRR为0.27±0.11 mmHg/mL/min,<60岁者为0.22±0.09 mmHg/mL/min(P=0.042)。
  • 肾脏存活率12个月为88.2% vs 84%,120个月为60.7% vs 30.8%(P=0.067)。
  • 供者≥60岁组中,GFR<30组FRR为0.37±0.08,GFR≥30组为0.18±0.06 mmHg/mL/min(P<0.001)。
  • FRR≥0.3 mmHg/mL/min预测GFR<30 mL/min的比值比(OR)为2.16(95%CI 1.80-6.40;P<0.001)。
  • FRR预测GFR的ROC曲线准确度为0.968(95%CI未报告具体区间),最佳截断值0.3 mmHg/mL/min。

关键数值与推荐

  • FRR≥0.3 mmHg/mL/min预测6个月GFR<30 mL/min的灵敏度67%、特异度100%、阳性预测值83%、阴性预测值92%。

临床怎么用

  • 对不可控心死亡供肾,可结合供者年龄≥60岁与FRR≥0.3 mmHg/mL/min评估移植后6个月肾功能不良风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The criteria for kidney suitability in uncontrolled donors after circulatory death (uDCD) procured after regional normothermic perfusion are based on macroscopic appearance and renal haemodynamic values with final renal resistance (FRR). However, these criteria have not been analysed to predict the future graft function. This study presents a model to predict the outcome in uDCD kidneys and define the predictive FRR value. METHODS: All uDCD kidney transplants performed in our hospital from 2004 to 2016 were included. Donors and recipients and pre-transplantation data are described. The endpoint was glomerular filtration rate (GFR) ≥30 mL/min at 6 months after transplantation. RESULTS: A total of 194 recipients were included. FRR in donors ≥60 years old was (mean ± SD) 0.27 ± 0.11 versus 0.22 ± 0.09 mmHg/mL/min in donors <60 years (P = 0.042). Kidney survival was 88.2% versus 84% at 12 months and 60.7% versus 30.8% at 120 months (P = 0.067). For the group of recipients from donors ≥60 years, the FRR was 0.37 ± 0.08 mmHg/mL/min in the GFR <30 mL/min group versus 0.18 ± 0.06 mmHg/mL/min in the GFR ≥30 mL/min group (P < 0.001). The value FRR ≥0.3 mmHg/mL/min predicts 59-79% of GFR <30 mL/min [odds ratio = 2.16, 95% confidence interval (CI) 1.80-6.40; P < 0.001]. The predictive accuracy of FRR for GFR by ROC curve was 0.968 (95% CI). The best cut-off for FRR was 0.3 mmHg/mL/min to predict GFR at 6 months with a sensitivity of 67%, specificity of 100%, positive predictive value of 83% and negative predictive value of 92%. CONCLUSIONS: Our results suggest that in uDCD donors the combination of donor age ≥60 years together with FRR ≥0.3 mmHg/mL/min could predict poor outcome at 6 months after transplantation in low immunological risk recipients.

来源:Nephrol Dial Transplant,查看原文。版权归原作者所有。

引用

  1. Gelpi R, Paredes D, Rodríguez-Villar C, et al. The development of a predictive model of graft function in uncontrolled donors after circulatory death: validity of a pulsatile renal preservation machine cut-off value for kidney acceptance. Nephrol Dial Transplant. 2019. PMID: 30085267. doi:10.1093/ndt/gfy241

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。