文献速递慢性肾脏病水电解质与酸碱

高PM2.5水平与环境温度与非透析5期CKD患者急性肺水肿相关

High particulate matter 2.5 levels and ambient temperature are associated with acute lung edema in patients with nondialysis Stage 5 chronic kidney disease.
PubMed 文献 · Nephrol Dial Transplant · 2019-01-01

本研究采用病例交叉设计,纳入台湾中部317例发生急性肺水肿并开始长期透析的5期非透析CKD患者。结果显示,秋季和冬季7天平均PM2.5水平与急性肺水肿发病率相关,冬季即使3天暴露也增加风险;春夏季3天平均温度与风险正相关,秋冬季温度与风险负相关。结论提示高PM2.5水平及极端环境温度增加急性肺水肿风险,应教育患者避免严重空气污染和极端温度环境。

要点

  • 秋季和冬季7天平均PM2.5水平与急性肺水肿风险增加相关。
  • 冬季即使3天PM2.5暴露也与风险增加相关。
  • 春夏季高温和秋冬季低温均与急性肺水肿风险增加相关。

核心结论

  • 高PM2.5水平与急性肺水肿风险增加相关。
  • 炎热季节高温和寒冷季节低温也与风险增加相关。
  • 应教育患者避免严重空气污染和极端温度环境。

研究设计与样本

  • 病例交叉研究,纳入317例台湾中部5期非透析CKD患者(eGFR 6.79 ± 4.56 mL/min),均发生急性肺水肿并开始长期透析。
  • 采用Pearson相关检验分别分析急性肺水肿病例与PM2.5水平和环境温度的关系。

主要发现

  • 秋季7天平均PM2.5水平与急性肺水肿发病率相关(调整OR 3.23,P = 0.047)。
  • 冬季7天平均PM2.5水平与急性肺水肿发病率相关(调整OR 1.99,P < 0.001);冬季3天PM2.5暴露也增加风险(调整OR 1.55,P < 0.001)。
  • 春夏季3天平均温度与风险正相关(调整OR 2.77,P < 0.001;调整OR 2.72,P < 0.001)。
  • 秋冬季温度与风险负相关(调整OR 0.36,P < 0.001;调整OR 0.54,P < 0.001)。

临床怎么用

  • 对5期非透析CKD患者,应教育其避免严重空气污染和极端温度环境。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Numerous studies have shown that exposure to air pollution, especially particulate matter (PM) with a diameter <2.5 μm (PM2.5), was associated with various diseases. We tried to determine the impact of PM2.5 and other weather factors on acute lung edema in patients with Stage 5 nondialysis chronic kidney disease (CKD Stage 5-ND). METHODS: In total, 317 CKD Stage 5-ND (estimated glomerular filtration rate 6.79 ± 4.56 mL/min) patients residing in central Taiwan who developed acute lung edema and initiated long-term dialysis were included in this case-crossover study. Pearson's correlation test was used to examine the relationship of acute lung edema cases with PM2.5 levels and ambient temperature separately. RESULTS: The average PM2.5 level within the 7-day period correlated with acute lung edema incidence in the fall [adjusted odds ratio (OR) 3.23, P = 0.047] and winter (adjusted OR 1.99, P < 0.001). In winter, even a 3-day exposure to PM2.5 was associated with increased risk (adjusted OR 1.55, P < 0.001). The average temperatures within 3 days in spring and summer were correlated positively with the risk (adjusted OR 2.77 P < 0.001 and adjusted OR 2.72, P < 0.001, respectively). In the fall and winter, temperatures were correlated negatively with the risk (adjusted OR 0.36, P < 0.001 and adjusted OR 0.54, P < 0.001, respectively). CONCLUSIONS: A high PM2.5 level was associated with an increased risk of acute lung edema. High ambient temperature in hot seasons and low ambient temperature in cold seasons were also associated with increased risk. It is essential to educate these patients to avoid areas with severe air pollution and extreme ambient temperature.

来源:Nephrol Dial Transplant,查看原文。版权归原作者所有。

引用

  1. Chiu PF, Chang CH, Wu CL, et al. High particulate matter 2.5 levels and ambient temperature are associated with acute lung edema in patients with nondialysis Stage 5 chronic kidney disease. Nephrol Dial Transplant. 2019. PMID: 29939300. doi:10.1093/ndt/gfy144

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。