近红外光谱连续监测儿童肾移植灌注
结果显示NIRS TOI%与DUS RI在上极(r=-0.4,P=0.04)和下极(r=-0.6,P=0.001)均呈显著负相关,收缩压也与TOI%相关(P=0.01)。NIRS耐受良好,有效测量率96-100%,提示其可评估移植肾灌注,但需进一步研究用于术后早期连续监测。
要点
- 儿童肾移植受者中NIRS TOI%与DUS RI上极r=-0.4、下极r=-0.6均显著负相关。
- NIRS监测耐受良好,有效测量率96-100%。
- 收缩压与NIRS TOI%相关(P=0.01),eGFR未显示相关。
核心结论
- NIRS组织氧合指数与DUS灌注及血流动力学参数在稳定期儿童肾移植受者中相关性良好。
主要发现
- NIRS TOI%与DUS RI在上极(r=-0.4,P=0.04)和下极(r=-0.6,P=0.001)均呈显著负相关。
- 收缩压与NIRS TOI%显著相关(P=0.01),而估算肾小球滤过率(eGFR)未显示与TOI%相关。
- NIRS监测所有受试者耐受良好,有效测量率为96-100%。
临床怎么用
- NIRS可作为儿童肾移植受者移植肾灌注的无创实时评估工具,但当前证据限于稳定期受者,尚不能替代DUS。
局限性
- 原文未报告NIRS与DUS对比的阈值、敏感度或特异度等诊断性能指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Current reliance on clinical, laboratory and Doppler ultrasound (DUS) parameters for monitoring kidney transplant perfusion in the immediate post-operative period in children risks late recognition of allograft hypoperfusion and vascular complications. Near-infrared spectroscopy (NIRS) is a real-time, non-invasive technique for monitoring tissue oxygenation percutaneously. NIRS monitoring of kidney transplant perfusion has not previously been validated to the gold standard of DUS. We examined whether NIRS tissue oxygenation indices can reliably assess blood flow in established paediatric kidney transplants. METHODS: Paediatric kidney transplant recipients ages 1-18 years with stable allograft function were eligible. Participants underwent routine DUS assessment of kidney transplant perfusion, including resistive index (RI) and peak systolic velocity at the upper and lower poles. NIRS data [tissue oxygenation index (TOI%)] were recorded for a minimum of 2 min with NIRS sensors placed on the skin over upper and lower allograft poles. RESULTS: Twenty-nine subjects with a median age of 13.3 (range 4.8-17.8) years and a median transplant vintage of 26.5 months participated. Thirteen (45%) were female and 20 (69%) were living donor kidney recipients. NIRS monitoring was well tolerated by all, with 96-100% valid measurements. Significant negative correlations were observed between NIRS TOI% and DUS RI at both the upper and lower poles (r = -0.4 and -0.6, P = 0.04 and 0.001, respectively). Systolic blood pressure but not estimated glomerular filtration rate also correlated with NIRS TOI% (P = 0.01). CONCLUSIONS: NIRS indices correlate well with DUS perfusion and haemodynamic parameters in established paediatric kidney transplant recipients. Further studies are warranted to extend NIRS use for continuous real-time monitoring of early post-transplant perfusion status.
引用
- Malakasioti G, Marks SD, Watson T, et al. Continuous monitoring of kidney transplant perfusion with near-infrared spectroscopy. Nephrol Dial Transplant. 2018. PMID: 29757424. doi:10.1093/ndt/gfy116
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。