文献速递血液净化与透析

中性pH低葡萄糖降解产物透析液对儿童腹膜透析腹膜早期改变的影响

Neutral pH and low-glucose degradation product dialysis fluids induce major early alterations of the peritoneal membrane in children on peritoneal dialysis.
PubMed 文献 · Kidney Int · 2018-01-01

该研究对56名肾功能正常儿童、90名插管时终末期肾病儿童和82名使用低葡萄糖降解产物透析液的腹膜透析儿童共256份标准化腹膜和172份大网膜标本进行自动定量组织形态学和分子分析,24名儿童在中位腹膜透析13个月后获得随访活检。结果显示,透析前已存在轻度腹膜炎症、上皮-间充质转化和血管病变;透析至6和12个月时,血液微血管密度分别增加110%和93%,内皮表面积/腹膜体积分别增加137%和95%,亚间皮厚度分别增加23%和58%,后续变化减弱。间皮细胞覆盖降低、血管病变进展,而淋巴管密度不变,形态学改变伴随早期成纤维细胞活化、白细胞和巨噬细胞浸润、弥漫性podoplanin表达、上皮间充质转分化及促血管生成和促纤维化细胞因子增多,个体内比较证实这些改变,腹膜微血管密度与腹膜小分子转运功能相关。

要点

  • 低葡萄糖降解产物中性pH透析液在儿童腹膜透析早期即可诱导腹膜炎症、成纤维细胞活化、上皮-间充质转化和显著血管生成。
  • 腹膜微血管密度与腹膜小分子转运功能相关,提示血管生成决定腹膜转运功能。
  • 透析前终末期肾病儿童已存在轻度腹膜炎症、上皮-间充质转化和血管病变。

核心结论

  • 在儿童腹膜透析中,含低葡萄糖降解产物的中性pH透析液诱导早期腹膜炎症、成纤维细胞活化、上皮-间充质转化和显著血管生成,并决定腹膜透析膜转运功能。

研究设计与样本

  • 对56名肾功能正常儿童、90名插管时终末期肾病儿童和82名使用低葡萄糖降解产物透析液的腹膜透析儿童的256份标准化腹膜和172份大网膜标本进行自动定量组织形态学和分子分析。
  • 对24名儿童在中位腹膜透析13个月后获取随访活检。

主要发现

  • 透析前已存在轻度腹膜炎症、上皮-间充质转化和血管病变。
  • 腹膜透析至6和12个月时,血液微血管密度分别增加110%和93%,内皮表面积/腹膜体积分别增加137%和95%,亚间皮厚度分别增加23%和58%。
  • 后续腹膜变化减弱,间皮细胞覆盖降低、血管病变进展,而淋巴管密度不变。
  • 形态学改变伴随早期成纤维细胞活化、白细胞和巨噬细胞浸润、弥漫性podoplanin表达、上皮间充质转分化及促血管生成和促纤维化细胞因子增多,个体内比较证实这些改变。
  • 腹膜微血管密度与腹膜小分子转运功能相关(单因素和多因素分析)。

临床怎么用

  • 儿童腹膜透析使用低葡萄糖降解产物中性pH透析液时,应关注早期腹膜炎症、血管生成和转运功能改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The effect of peritoneal dialysates with low-glucose degradation products on peritoneal membrane morphology is largely unknown, with functional relevancy predominantly derived from experimental studies. To investigate this, we performed automated quantitative histomorphometry and molecular analyses on 256 standardized peritoneal and 172 omental specimens from 56 children with normal renal function, 90 children with end-stage kidney disease at time of catheter insertion, and 82 children undergoing peritoneal dialysis using dialysates with low-glucose degradation products. Follow-up biopsies were obtained from 24 children after a median peritoneal dialysis of 13 months. Prior to dialysis, mild parietal peritoneal inflammation, epithelial-mesenchymal transition and vasculopathy were present. After up to six and 12 months of peritoneal dialysis, blood microvessel density was 110 and 93% higher, endothelial surface area per peritoneal volume 137 and 95% greater, and submesothelial thickness 23 and 58% greater, respectively. Subsequent peritoneal changes were less pronounced. Mesothelial cell coverage was lower and vasculopathy advanced, whereas lymphatic vessel density was unchanged. Morphological changes were accompanied by early fibroblast activation, leukocyte and macrophage infiltration, diffuse podoplanin presence, epithelial mesenchymal transdifferentiation, and by increased proangiogenic and profibrotic cytokine abundance. These transformative changes were confirmed by intraindividual comparisons. Peritoneal microvascular density correlated with peritoneal small-molecular transport function by uni- and multivariate analysis. Thus, in children on peritoneal dialysis neutral pH dialysates containing low-glucose degradation products induce early peritoneal inflammation, fibroblast activation, epithelial-mesenchymal transition and marked angiogenesis, which determines the PD membrane transport function.

来源:Kidney Int,查看原文。版权归原作者所有。

引用

  1. Schaefer B, Bartosova M, Macher-Goeppinger S, et al. Neutral pH and low-glucose degradation product dialysis fluids induce major early alterations of the peritoneal membrane in children on peritoneal dialysis. Kidney Int. 2018. PMID: 29776755. doi:10.1016/j.kint.2018.02.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。