文献速递慢性肾脏病遗传性与小管间质肾病

生物标志物与影像学对肾性骨营养不良骨转换的诊断准确性

Diagnostic Accuracy of Biomarkers and Imaging for Bone Turnover in Renal Osteodystrophy.
PubMed 文献 · J Am Soc Nephrol · 2018-03-19

该研究纳入69例CKD 4-5期患者(含透析)和68例对照,用骨活检组织形态学作为金标准,评估骨生物标志物和HR-pQCT参数预测骨转换状态的能力。结果显示bALP、完整PINP和TRAP5b及桡骨HR-pQCT参数可区分低骨转换与非低骨转换,iPTH对低骨转换诊断准确性差但可区分高骨转换。

要点

  • bALP、完整PINP和TRAP5b区分低骨转换的AUC分别为0.82、0.79和0.80,优于iPTH的0.61。
  • 桡骨HR-pQCT总容积骨密度和皮质骨体积区分低骨转换的AUC分别为0.81和0.80。
  • iPTH区分高骨转换的AUC为0.76,与其他生物标志物(包括CTX)相似。

核心结论

  • bALP、完整PINP、TRAP5b和桡骨HR-pQCT参数可区分低骨转换与非低骨转换。
  • iPTH对低骨转换诊断准确性差,但区分高骨转换的准确性与其它生物标志物相似。

研究设计与样本

  • 研究纳入69例CKD 4-5期患者(包括透析患者)和68例对照进行生物标志物分析。
  • 对43例CKD患者进行骨活检组织形态学评估作为金标准。
  • 检测空腹血iPTH、PINP、bALP、CTX和TRAP5b,并行桡骨和胫骨HR-pQCT扫描。

主要发现

  • CKD样本中所有检测的生物标志物水平均显著高于对照样本。
  • 区分低骨转换时,bALP、完整PINP和TRAP5b的AUC分别为0.82、0.79和0.80,均显著优于iPTH的AUC 0.61。
  • 桡骨HR-pQCT总容积骨密度和皮质骨体积的AUC分别为0.81和0.80。
  • 区分高骨转换时,iPTH的AUC为0.76,与所有其他检测的生物标志物相似。

临床怎么用

  • 对于CKD 4-5期患者,可考虑使用bALP、完整PINP、TRAP5b或桡骨HR-pQCT参数辅助评估低骨转换状态。
  • iPTH不适用于诊断低骨转换,但可用于区分高骨转换。

局限性

  • 骨活检组织形态学分析仅纳入43例CKD患者,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background Renal osteodystrophy is common in advanced CKD, but characterization of bone turnover status can only be achieved by histomorphometric analysis of bone biopsy specimens (gold standard test). We tested whether bone biomarkers and high-resolution peripheral computed tomography (HR-pQCT) parameters can predict bone turnover status determined by histomorphometry.Methods We obtained fasting blood samples from 69 patients with CKD stages 4-5, including patients on dialysis, and 68 controls for biomarker analysis (intact parathyroid hormone [iPTH], procollagen type 1 N-terminal propeptide [PINP], bone alkaline phosphatase [bALP], collagen type 1 crosslinked C-telopeptide [CTX], and tartrate-resistant acid phosphatase 5b [TRAP5b]) and scanned the distal radius and tibia of participants by HR-pQCT. We used histomorphometry to evaluate bone biopsy specimens from 43 patients with CKD.Results Levels of all biomarkers tested were significantly higher in CKD samples than control samples. For discriminating low bone turnover, bALP, intact PINP, and TRAP5b had an areas under the receiver operating characteristic curve (AUCs) of 0.82, 0.79, and 0.80, respectively, each significantly better than the iPTH AUC of 0.61. Furthermore, radius HR-pQCT total volumetric bone mineral density and cortical bone volume had AUCs of 0.81 and 0.80, respectively. For discriminating high bone turnover, iPTH had an AUC of 0.76, similar to that of all other biomarkers tested.Conclusions The biomarkers bALP, intact PINP, and TRAP5b and radius HR-pQCT parameters can discriminate low from nonlow bone turnover. Despite poor diagnostic accuracy for low bone turnover, iPTH can discriminate high bone turnover with accuracy similar to that of the other biomarkers, including CTX.

来源:J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Salam S, Gallagher O, Gossiel F, et al. Diagnostic Accuracy of Biomarkers and Imaging for Bone Turnover in Renal Osteodystrophy. J Am Soc Nephrol. 2018. PMID: 29555831. doi:10.1681/ASN.2017050584

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。