唾液尿素氮试纸检测马拉维产科相关急性肾病的诊断性能
在马拉维布兰太尔产科病房纳入301例高危孕妇,评估唾液尿素氮(SUN)试纸诊断产科相关急性肾病的性能。SUN>14 mg/dl检测急性肾病的敏感性12.82%、特异性97.33%,AUC为0.551。试纸特异性高但敏感性低,可能与妊娠生理变化导致生化异常程度轻和唾液尿素浓度低有关。
要点
- SUN试纸诊断产科相关急性肾病特异性高(97.33%)但敏感性低(12.82%)。
- SUN>14 mg/dl时AUC仅0.551,诊断价值有限。
- 敏感性低可能与妊娠生理变化致唾液尿素浓度低有关。
核心结论
- SUN试纸诊断产科相关急性肾病特异性高但敏感性低,AUC为0.551。
- 敏感性低可能归因于妊娠生理变化导致生化异常程度轻和唾液尿素浓度低,而非试纸技术限制。
研究设计与样本
- 前瞻性诊断性能研究,2015年9月21日至12月11日在马拉维布兰太尔产科病房招募301例AKI高危孕妇。
- 入院时及之后每48小时(如发现肾脏病证据)检测血清肌酐和SUN试纸。
主要发现
- 301例患者平均年龄25.9岁,11% HIV阳性;23例(7.6%)发生AKI,其中47.8%为1期,最常见病因为子痫前期/子痫。
- AKI 1至3期平均就诊血清肌酐分别为108.8 ± 21.8 μmol/l(1.23 ± 0.25 mg/dl)、118 ± 34.45 μmol/l(1.33 ± 0.39 mg/dl)和136.1 ± 30.4 μmol/l(1.54 ± 0.34 mg/dl)。
- SUN > 14 mg/dl检测急性肾病的敏感性为12.82%,特异性为97.33%,AUC为0.551。
- 入院SUN正常者围产期死亡率为11.8%,SUN > 14 mg/dl者为25.0%(P = 0.18)。
关键数值与推荐
- SUN > 14 mg/dl作为急性肾病检测阈值:敏感性12.82%,特异性97.33%,AUC 0.551。
- AKI分期依据血清肌酐均值:1期108.8 ± 21.8 μmol/l,2期118 ± 34.45 μmol/l,3期136.1 ± 30.4 μmol/l。
临床怎么用
- SUN试纸因敏感性低不适用于产科相关急性肾病的筛查或诊断。
- 在高危孕妇中仍需依赖血清肌酐检测来识别AKI。
局限性
- 敏感性低可能受妊娠生理变化影响,限制了试纸在该人群的诊断效用。
- 围产期死亡率差异P = 0.18,未达统计学显著性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Obstetric-related acute kidney injury (AKI) is associated with adverse outcomes for mother and fetus, particularly in low-income countries. However, laboratory-independent tools to facilitate diagnosis are lacking. We assessed the diagnostic performance of a salivary urea nitrogen (SUN) dipstick to detect obstetric-related acute kidney disease in Malawi. METHODS: Women at high risk for AKI admitted to an obstetric unit in Blantyre, Malawi, were recruited between 21 September and 11 December 2015. Patients underwent serum creatinine (SCr) testing alongside measurement of SUN using a dipstick on admission, and every 48 hours thereafter if evidence of kidney disease was found. RESULTS: A total of 301 patients were included (mean age 25.9 years, 11% HIV positive). Of the patients, 23 (7.6%) had AKI, stage 1 in 47.8%, most commonly due to preeclampsia/eclampsia. Mean presenting SCr values were 108.8 ± 21.8 μmol/l (1.23 ± 0.25 mg/dl), 118 ± 34.45 μmol/l (1.33 ± 0.39 mg/dl), and 136.1 ± 30.4 μmol/l (1.54 ± 0.34 mg/dl) in AKI stages 1 to 3 respectively. SUN > 14 mg/dl had a sensitivity of 12.82% and a specificity of 97.33% to detect acute kidney disease; the area under the receiver operating characteristic curve was 0.551. In patients with normal SUN on admission, perinatal mortality was 11.8%, and was 25.0% if SUN was > 14 mg/dl (P = 0.18). CONCLUSION: The SUN dipstick was specific but insensitive when used to diagnose obstetric-related AKI. Limited biochemical derangement and low salivary urea concentrations due to physiological changes in pregnancy, as opposed to a technical limitation of the dipstick itself, are the likely reason for the lack of sensitivity in this study.
引用
- Evans RDR, Cooke W, Hemmila U, et al. A Salivary Urea Nitrogen Dipstick to Detect Obstetric-Related Acute Kidney Disease in Malawi. Kidney Int Rep. 2017. PMID: 29340329. doi:10.1016/j.ekir.2017.10.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。