文献速递慢性肾脏病

尿阴离子间隙预测尿铵及肾脏病结局

Urine Anion Gap to Predict Urine Ammonium and Related Outcomes in Kidney Disease.
PubMed 文献 · Clin J Am Soc Nephrol · 2017-11-02

在1044例非洲裔美国肾脏病与高血压研究参与者中,标准尿阴离子间隙与尿铵相关性弱(r=0.18),而纳入磷酸盐和硫酸盐的改良尿阴离子间隙与尿铵呈中度负相关(r=-0.58)。最低尿铵三分位者ESRD或死亡风险更高(HR 1.46),改良尿阴离子间隙对应三分位风险近似(HR 1.32),标准尿阴离子间隙无此关联。

要点

  • 标准尿阴离子间隙不是尿铵的良好替代指标。
  • 改良尿阴离子间隙需纳入磷酸盐和硫酸盐。
  • 直接测尿铵仍优于改良尿阴离子间隙估算。

核心结论

  • 在CKD中,除非计算中纳入磷酸盐和硫酸盐,否则尿阴离子间隙是尿铵的差替代指标。

研究设计与样本

  • 在1044例非洲裔美国肾脏病与高血压研究参与者中,测量基线24小时尿液的铵、钠、钾、氯、磷酸盐和硫酸盐。

主要发现

  • 标准尿阴离子间隙与尿铵直接相关性弱(r=0.18)。
  • 改良尿阴离子间隙与尿铵呈中度负相关(r=-0.58)。
  • 最低尿铵三分位者ESRD或死亡风险更高(HR 1.46;95%CI 1.13-1.87)。
  • 标准尿阴离子间隙对应三分位无更高风险(HR 0.82;95%CI 0.64-1.07)。
  • 改良尿阴离子间隙对应三分位风险近似尿铵(HR 1.32;95%CI 1.03-1.68)。

临床怎么用

  • CKD中直接测量尿铵优于使用改良尿阴离子间隙估算。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Low urine ammonium excretion is associated with ESRD in CKD. Few laboratories measure urine ammonium, limiting clinical application. We determined correlations between urine ammonium, the standard urine anion gap, and a modified urine anion gap that includes sulfate and phosphate and compared risks of ESRD or death between these ammonium estimates and directly measured ammonium. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We measured ammonium, sodium, potassium, chloride, phosphate, and sulfate from baseline 24-hour urine collections in 1044 African-American Study of Kidney Disease and Hypertension participants. We evaluated the cross-sectional correlations between urine ammonium, the standard urine anion gap (sodium + potassium - chloride), and a modified urine anion gap that includes urine phosphate and sulfate in the calculation. Multivariable-adjusted Cox models determined the associations of the standard urine anion gap and the modified urine anion gap with the composite end point of death or ESRD; these results were compared with results using urine ammonium as the predictor of interest. RESULTS: The standard urine anion gap had a weak and direct correlation with urine ammonium (r=0.18), whereas the modified urine anion gap had a modest inverse relationship with urine ammonium (r=-0.58). Compared with the highest tertile of urine ammonium, those in the lowest urine ammonium tertile had higher risk of ESRD or death (hazard ratio, 1.46; 95% confidence interval, 1.13 to 1.87) after adjusting for demographics, GFR, proteinuria, and other confounders. In comparison, participants in the corresponding standard urine anion gap tertile did not have higher risk of ESRD or death (hazard ratio, 0.82; 95% confidence interval, 0.64 to 1.07), whereas the risk for those in the corresponding modified urine anion gap tertile (hazard ratio, 1.32; 95% confidence interval, 1.03 to 1.68) approximated that of directly measured urine ammonium. CONCLUSIONS: Urine anion gap is a poor surrogate of urine ammonium in CKD unless phosphate and sulfate are included in the calculation. Because the modified urine anion gap merely estimates urine ammonium and requires five measurements, direct measurements of urine ammonium are preferable in CKD.

来源:Clin J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Raphael KL, Gilligan S, Ix JH, et al. Urine Anion Gap to Predict Urine Ammonium and Related Outcomes in Kidney Disease. Clin J Am Soc Nephrol. 2017. PMID: 29097482. doi:10.2215/CJN.03770417

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。