血液透析患者微量元素浓度:一项前瞻性队列研究
该研究从加拿大3个中心的前瞻性队列中随机抽取198例新发血液透析患者,用质谱法在基线、6个月、1年和2年时测定血浆25种元素浓度。结果显示低锌、低硒、低锰并不常见,而铅浓度超标极为普遍,部分患者砷和汞浓度超标。
要点
- 多数加拿大血透患者不存在低锌、低硒或低锰血症。
- 铅浓度超过健康参考人群第95百分位的现象极为普遍。
- 部分患者砷和汞浓度超标,需进一步研究。
核心结论
- 没有证据表明大多数当代加拿大血透患者存在低锌、低硒或低锰浓度。
- 部分患者血浆砷和汞浓度超标,铅浓度超标常见,需进一步研究。
研究设计与样本
- 前瞻性队列研究,随机抽取198例在3个加拿大中心治疗的新发血液透析患者。
- 用质谱法在基线、6个月、1年和2年时测定血浆25种元素浓度。
主要发现
- 在所有4个时间点,低锌、低硒、低锰浓度不常见,分别≤5.1%、≤1.8%、≤0.9%。
- 超过第95百分位的比例分别为锌≥65.2%、硒≥74.2%、锰≥19.7%。
- 几乎所有参与者在所有时间点血浆铅浓度均高于第95百分位。
- 血浆砷浓度超过第95百分位的比例随时间相对稳定(9.1%-9.8%),汞浓度超过第95百分位的比例在15.2%至29.3%之间变化。
- 低砷、铂、钨、铍浓度常见(>50%),高钴、锰、锌、钒、镉、硒、钡、锑、镍、钼、铅、铬浓度也常见。
关键数值与推荐
- 低浓度和超标浓度分别基于健康参考人群血浆浓度的第5和第95百分位。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Low concentrations and excessive concentrations of trace elements have been commonly reported in hemodialysis patients, but available studies have several important limitations. STUDY DESIGN: Random sample of patients drawn from a prospective cohort. SETTING & PARTICIPANTS: 198 incident hemodialysis patients treated in 3 Canadian centers. MEASUREMENTS: We used mass spectrometry to measure plasma concentrations of the 25 elements at baseline, 6 months, 1 year, and 2 years following enrollment in the cohort. We focused on low concentrations of zinc, selenium, and manganese and excessive concentrations of lead, arsenic, and mercury; low and excessive concentrations of the other 19 trace elements were treated as exploratory analyses. Low and excessive concentrations were based on the 5th and 95th percentile plasma concentrations from healthy reference populations. RESULTS: At all 4 occasions, low zinc, selenium, and manganese concentrations were uncommon in study participants (≤5.1%, ≤1.8%, and ≤0.9% for zinc, selenium, and manganese, respectively) and a substantial proportion of participants had concentrations that exceeded the 95th percentile (≥65.2%, ≥74.2%, and ≥19.7%, respectively). Almost all participants had plasma lead concentrations above the 95th percentile at all time points. The proportion of participants with plasma arsenic concentrations exceeding the 95th percentile was relatively constant over time (9.1%-9.8%); the proportion with plasma mercury concentrations that exceeded the 95th percentile varied between 15.2% and 29.3%. Low arsenic, platinum, tungsten, and beryllium concentrations were common (>50%), as were excessive cobalt, manganese, zinc, vanadium, cadmium, selenium, barium, antimony, nickel, molybdenum, lead, and chromium concentrations. CONCLUSIONS: There was no evidence that low zinc, selenium, or manganese concentrations exist in most contemporary Canadian hemodialysis patients. Some patients have excessive plasma arsenic and mercury concentrations, and excessive lead concentrations were common. These findings require further investigation.
引用
- Tonelli M, Wiebe N, Bello A, et al. Concentrations of Trace Elements in Hemodialysis Patients: A Prospective Cohort Study. Am J Kidney Dis. 2017. PMID: 28838766. doi:10.1053/j.ajkd.2017.06.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。