基于HEMO研究的透析患者肌酐生成率动力学建模:是否需要透析后血肌酐检测
该研究利用HEMO研究366次透析的数据,验证两池动力学模型预测肌酐浓度及生成率,并比较需要与不需要透析后血肌酐的简化方法。结果显示简化方法与正式建模的肌酐生成率高度一致(R²=0.971),提示可免去透析后血肌酐检测。
要点
- 尿素与肌酐透析器清除率高度相关(R²=0.78)。
- 考虑肾外清除后,透析患者肌酐生成率与非透析患者相似。
- 基于尿素清除率和分布容积的简化方法可准确估算肌酐生成率。
核心结论
- 透析患者肌酐生成率与非透析患者相似,简化方法无需透析后血肌酐即可获得与正式建模高度一致的肌酐生成率(R²=0.971)。
研究设计与样本
- 研究纳入HEMO研究随访第4个月的366次透析,使用两池动力学模型,模型包含肾外肌酐清除率0.038 L/kg/24h。
主要发现
- 尿素与肌酐透析器清除率分别为230(SD 37)mL/min和164(SD 30)mL/min,R²=0.78。
- 计算得肌酐分布容积平均29.6(SD 7.2)L,尿素为31.6(SD 7.0)L(P<0.01)。
- 建模肌酐生成率平均1183(SD 463)mg/day,为非透析患者人体测量方程预测值的100.1%(SD 29;中位数99.3%)。
- 简化方法(使用尿素分布容积和尿素清除率,不检测透析后血肌酐)得肌酐生成率1187(SD 475)mg/day,与正式建模值R²=0.971。
临床怎么用
- 临床可采用基于尿素清除率和尿素分布容积的简化方法估算透析患者肌酐生成率,无需透析后血肌酐检测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. METHODS: We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. RESULTS: Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P < 0.01). The modeled creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. CONCLUSIONS: Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance and urea distribution volume not requiring a postdialysis serum creatinine measurement can be used to yield creatinine generation rates that closely match those determined from standard modeling.
引用
- Daugirdas JT, Depner TA. Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study. Nephrol Dial Transplant. 2017. PMID: 28379486. doi:10.1093/ndt/gfx038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。