文献速递血液净化与透析

透析中磁共振成像评估血液透析滤过与血液透析对心血管反应的短期试验

Intradialytic Cardiac Magnetic Resonance Imaging to Assess Cardiovascular Responses in a Short-Term Trial of Hemodiafiltration and Hemodialysis.
PubMed 文献 · J Am Soc Nephrol · 2016-11-10

该随机交叉研究纳入12例稳定血液透析患者,比较标准血液透析与血液透析滤过对透析中心血管急性反应的影响,采用透析中心脏磁共振成像评估。两种模式超滤率和降温程度相似,收缩功能指标在两者中均下降且透析后部分恢复,所有患者出现节段性左室功能障碍,心肌灌注在两者中均显著下降,治疗模式对任何心血管反应均无影响。

要点

  • 血液透析和血液透析滤过均导致收缩功能指标下降,透析后部分恢复。
  • 所有患者出现节段性左室功能障碍,严重程度与超滤率和血压下降成比例。
  • 两种模式中心肌灌注均显著下降,治疗模式对心血管反应无影响。

核心结论

  • 在采用冷却透析液的随机交叉研究中,透析中磁共振成像评估显示血液透析滤过与血液透析的心血管反应无显著差异。

研究设计与样本

  • 随机交叉研究,12例稳定血液透析患者(年龄32-72岁)随机分配至血液透析或血液透析滤过,稳定2周后透析中行心脏磁共振成像,随后交叉至另一模式并在2周后再次扫描。

主要发现

  • 血液透析期间超滤率为3.8±2.9 ml/kg per hour,血液透析滤过期间为4.4±2.5 ml/kg per hour(P=0.29),两种模式降温程度相似。
  • 所有收缩功能指标在血液透析和血液透析滤过期间均下降,透析后部分恢复。
  • 所有患者均出现一定程度的节段性左室功能障碍,严重程度与超滤率和血压下降成比例。
  • 心肌灌注在血液透析和血液透析滤过期间均显著下降。
  • 治疗模式对透析的任何心血管反应均无影响。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Hemodynamic stress during hemodialysis (HD) results in recurrent segmental ischemic injury (myocardial stunning) that drives cumulative cardiac damage. We performed a fully comprehensive study of the cardiovascular effect of dialysis sessions using intradialytic cardiac magnetic resonance imaging (MRI) to examine the comparative acute effects of standard HD versus hemodiafiltration (HDF) in stable patients. We randomly allocated 12 patients on HD (ages 32-72 years old) to either HD or HDF. Patients were stabilized on a modality for 2 weeks before undergoing serial cardiac MRI assessment during dialysis. Patients then crossed over to the other modality and were rescanned after 2 weeks. Cardiac MRI measurements included cardiac index, stroke volume index, global and regional contractile function (myocardial strain), coronary artery flow, and myocardial perfusion. Patients had mean±SEM ultrafiltration rates of 3.8±2.9 ml/kg per hour during HD and 4.4±2.5 ml/kg per hour during HDF (P=0.29), and both modalities provided a similar degree of cooling. All measures of systolic contractile function fell during HD and HDF, with partial recovery after dialysis. All patients experienced some degree of segmental left ventricular dysfunction, with severity proportional to ultrafiltration rate and BP reduction. Myocardial perfusion decreased significantly during HD and HDF. Treatment modality did not influence any of the cardiovascular responses to dialysis. In conclusion, in this randomized, crossover study, there was no significant difference in the cardiovascular response to HDF or HD with cooled dialysate as assessed with intradialytic MRI.

来源:J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Buchanan C, Mohammed A, Cox E, et al. Intradialytic Cardiac Magnetic Resonance Imaging to Assess Cardiovascular Responses in a Short-Term Trial of Hemodiafiltration and Hemodialysis. J Am Soc Nephrol. 2016. PMID: 28122851. doi:10.1681/ASN.2016060686

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。