血液透析急症的诊断、治疗与预防
本文综述血液透析过程中可能发生的重大急症,包括透析失衡综合征、静脉空气栓塞、溶血、静脉针脱出、血管通路出血、透析器或治疗药物过敏反应及透析水系统污染,阐述其发病机制、 minimization 措施及紧急干预方法,并介绍事件发生后的根本原因分析以预防复发。
要点
- 现代透析机安全特性、透析液严格处理与员工培训使透析急症发生率低,多数急症源于人为错误。
- 透析急症包括透析失衡综合征、静脉空气栓塞、溶血、静脉针脱出、血管通路出血、过敏反应及水系统污染。
- 事件发生后应进行根本原因分析以预防未来复发。
核心结论
- 血液透析急症虽罕见,但多数源于人为错误,少数为特异质反应,需通过最小化措施和紧急干预预防灾难性后果。
研究设计与样本
- 综述,检索范围未在摘要中报告。
主要发现
- 透析急症低发生率归因于现代透析机的多项安全特性、透析液细致处理与检测、详细治疗规程依从性及员工广泛培训。
- 多数血液透析急症可归因于人为错误,少数由罕见特异质反应引起。
关键数值与推荐
- 原文未报告具体标准与数值。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Given the high comorbidity in patients on hemodialysis and the complexity of the dialysis treatment, it is remarkable how rarely a life-threatening complication occurs during dialysis. The low rate of dialysis emergencies can be attributed to numerous safety features in modern dialysis machines; meticulous treatment and testing of the dialysate solution to prevent exposure to trace elements, toxins, and pathogens; adherence to detailed treatment protocols; and extensive training of dialysis staff to handle medical emergencies. Most hemodialysis emergencies can be attributed to human error. A smaller number are due to rare idiosyncratic reactions. In this review, we highlight major emergencies that may occur during hemodialysis treatments, describe their pathogenesis, offer measures to minimize them, and provide specific interventions to prevent catastrophic consequences on the rare occasions when such emergencies arise. These emergencies include dialysis disequilibrium syndrome, venous air embolism, hemolysis, venous needle dislodgement, vascular access hemorrhage, major allergic reactions to the dialyzer or treatment medications, and disruption or contamination of the dialysis water system. Finally, we describe root cause analysis after a dialysis emergency has occurred to prevent a future recurrence.
引用
- Saha M, Allon M. Diagnosis, Treatment, and Prevention of Hemodialysis Emergencies. Clin J Am Soc Nephrol. 2016. PMID: 27831511. doi:10.2215/CJN.05260516
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。