文献速递血液净化与透析

术前灌肠预防腹膜透析导管功能障碍的随机临床试验

Randomized Clinical Trial on the Efficacy and Safety of Preoperative Enema in the Prevention of Peritoneal Dialysis Catheter Dysfunction.
PubMed 文献 · Kidney Int Rep · 2026-03-06

这项单中心随机对照试验纳入136例腹膜透析置管患者,比较术前24小时内灌肠与不进行肠道准备的效果。结果显示灌肠组3个月内需干预的导管功能障碍发生率显著降低(14.7% vs 对照组,校正RR 0.299,95%CI 0.121-0.737,P=0.009),且未增加并发症。结论支持将肠道准备纳入腹膜透析置管术前常规方案。

要点

  • 术前灌肠可显著降低腹膜透析置管后3个月内需干预的导管功能障碍风险。
  • 灌肠组导管生存时间优于对照组(log-rank P=0.0015)。
  • 灌肠未增加感染及非感染性并发症的发生率。

核心结论

  • 术前灌肠显著降低早期腹膜透析导管功能障碍风险,且不增加并发症率。
  • 研究结果支持将肠道准备纳入腹膜透析置管的标准术前方案。

研究设计与样本

  • 前瞻性、单中心随机对照试验,共纳入136例接受腹膜透析置管的患者。
  • 患者随机分为术前24小时内灌肠组(n=68)或无肠道准备对照组(n=68)。
  • 主要终点为术后3个月内需干预的导管功能障碍发生率。

主要发现

  • 灌肠组3个月内需干预的导管功能障碍发生率为10/68(14.7%),显著低于对照组(未校正RR 0.297,95%CI 0.129-0.682,P=0.004;校正RR 0.299,95%CI 0.121-0.737,P=0.009)。
  • Kaplan-Meier分析显示灌肠组导管生存时间较对照组更长(log-rank P=0.0015)。
  • 仅1例对照组患者(1.5%)需要手术修正。
  • 两组在其他感染性和非感染性并发症方面无统计学显著差异。

关键数值与推荐

  • 主要终点:术后3个月内需干预的导管功能障碍发生率,灌肠组14.7% vs 对照组,校正RR 0.299(95%CI 0.121-0.737,P=0.009)。
  • 导管生存时间:灌肠组优于对照组,log-rank P=0.0015。
  • 手术修正率:仅对照组1例(1.5%)需手术修正。

临床怎么用

  • 可考虑在腹膜透析置管术前24小时内对患者进行灌肠肠道准备,以降低早期导管功能障碍风险。
  • 术前灌肠未增加感染及非感染性并发症,安全性可接受。

局限性

  • 本研究为单中心试验,样本量有限(136例),结果外推需谨慎。
  • 排除2例患者(1例阴囊渗漏和1例急性肾损伤)后完成6个月随访分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Current clinical practice guidelines do not universally recommend bowel preparation for peritoneal dialysis (PD) catheter insertion. This randomized controlled trial aimed to evaluate the efficacy and safety of preoperative enema in preventing PD catheter dysfunction. METHODS: In this prospective, single-center trial, 136 patients undergoing PD catheterization were randomly assigned to receive either preoperative enema within 24 hours (enema group, n = 68) or no bowel preparation (control group, n = 68). The primary end point was the incidence of catheter dysfunction requiring intervention within 3 months postoperation. Secondary outcomes encompassed the incidence of catheter dysfunction requiring intervention in 6 months, catheter event free survival time, the incidence of PD-associated peritonitis, and other catheter-related complications. RESULTS: One hundred thirty-four participants completed the 6-month follow-up after excluding 2 patients (1 with scrotal leakage and 1 with acute kidney injury). Baseline characteristics showed no significant intergroup differences. The enema group demonstrated significantly lower incidence of catheter dysfunction requiring intervention at 3 months (10/68 [14.7%], unadjusted risk ratio (RR): 0.297, [95% confidence interval (CI): 0.129-0.682], P = 0.004; adjusted RR 0.299 [95% CI: 0.121-0.737], P = 0.009). Kaplan-Meier analysis revealed longer catheter survival time in the enema group versus controls (log-rank P = 0.0015). Only 1 control patient (1.5%) required surgical revision. There was no statistically significant difference between the 2 groups in terms of other infection and noninfection complications. CONCLUSION: Preoperative enema significantly reduces early PD catheter dysfunction risk without increasing complication rates. These findings support incorporating bowel preparation into standard preoperative protocols for PD catheter placement.

来源:Kidney Int Rep,查看原文。版权归原作者所有。

引用

  1. Zhao L, Zhao J, Xing Y, et al. Randomized Clinical Trial on the Efficacy and Safety of Preoperative Enema in the Prevention of Peritoneal Dialysis Catheter Dysfunction. Kidney Int Rep. 2026. PMID: 42006215. doi:10.1016/j.ekir.2026.106464

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。