文献速递水电解质与酸碱

人工智能增强心电图在高急性度医疗环境中检测高钾血症的验证

Validation of Noninvasive Detection of Hyperkalemia by Artificial Intelligence-Enhanced Electrocardiography in High Acuity Settings.
PubMed 文献 · Clin J Am Soc Nephrol · 2024-06-21

本研究在急诊科和ICU两个高急性度队列中验证了人工智能心电图算法检测高钾血症(钾>6.0 mEq/L)的性能。结果显示该算法具有高阴性预测值(急诊99.8%、ICU 99%),但阳性预测值较低(急诊3%、ICU 14%),提示其适用于排除高钾血症而非直接指导治疗。

要点

  • AI-ECG算法在急诊和ICU队列中检测高钾血症的AUC均为0.88。
  • 高阴性预测值(99.8%和99%)支持其用于排除高钾血症。
  • 低阳性预测值(3%和14%)提示不能仅凭此治疗高钾血症。

核心结论

  • AI-ECG算法具有高阴性预测值,可用于排除高钾血症,但阳性预测值低,不足以指导治疗。

研究设计与样本

  • 急诊科队列(2021年2月至8月,N=40,128)和混合ICU队列(2017年8月至2018年2月,N=2,636)分别分析,配对4小时内实验室钾和12导联心电图。

主要发现

  • 急诊队列中高钾血症(钾>6.0 mEq/L)患病率为1%(N=351),AI-ECG的AUC为0.88,灵敏度80%、特异度80%、PPV 3%、NPV 99.8%、LR+ 4.0。
  • 急诊队列低eGFR(<30 ml/min)亚组分析:AUC 0.83,灵敏度86%、特异度60%、PPV 15%、NPV 98%、LR+ 2.2。
  • ICU队列中高钾血症患病率为3%(N=87),AI-ECG的AUC为0.88,灵敏度82%、特异度82%、PPV 14%、NPV 99%、LR+ 4.6。
  • ICU队列低eGFR亚组分析:AUC 0.85,灵敏度88%、特异度67%、PPV 29%、NPV 97%、LR+ 2.7。

临床怎么用

  • AI-ECG可作为高钾血症的排除工具,高NPV有助于快速筛查低风险患者。
  • 由于PPV低,阳性结果需结合实验室血钾确认,不能直接用于治疗决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Artificial intelligence (AI) electrocardiogram (ECG) analysis can enable detection of hyperkalemia. In this validation, we assessed the algorithm's performance in two high acuity settings. METHODS: An emergency department (ED) cohort (February to August 2021) and a mixed intensive care unit (ICU) cohort (August 2017 to February 2018) were identified and analyzed separately. For each group, pairs of laboratory-collected potassium and 12 lead ECGs obtained within 4 hours of each other were identified. The previously developed AI ECG algorithm was subsequently applied to leads 1 and 2 of the 12 lead ECGs to screen for hyperkalemia (potassium >6.0 mEq/L). RESULTS: The ED cohort (N=40,128) had a mean age of 60 years, 48% were male, and 1% (N=351) had hyperkalemia. The area under the curve (AUC) of the AI-enhanced ECG (AI-ECG) to detect hyperkalemia was 0.88, with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive likelihood ratio (LR+) of 80%, 80%, 3%, 99.8%, and 4.0, respectively, in the ED cohort. Low-eGFR (<30 ml/min) subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.83, 86%, 60%, 15%, 98%, and 2.2, respectively, in the ED cohort. The ICU cohort (N=2636) had a mean age of 65 years, 60% were male, and 3% (N=87) had hyperkalemia. The AUC for the AI-ECG was 0.88 and yielded sensitivity, specificity, PPV, NPV, and LR+ of 82%, 82%, 14%, 99%, and 4.6, respectively in the ICU cohort. Low-eGFR subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.85, 88%, 67%, 29%, 97%, and 2.7, respectively in the ICU cohort. CONCLUSIONS: The AI-ECG algorithm demonstrated a high NPV, suggesting that it is useful for ruling out hyperkalemia, but a low PPV, suggesting that it is insufficient for treating hyperkalemia.

来源:Clin J Am Soc Nephrol,查看原文。版权归原作者所有。

引用

  1. Harmon DM, Liu K, Dugan J, et al. Validation of Noninvasive Detection of Hyperkalemia by Artificial Intelligence-Enhanced Electrocardiography in High Acuity Settings. Clin J Am Soc Nephrol. 2024. PMID: 39116276. doi:10.2215/CJN.0000000000000483

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。