新型环保血液透析处方的安全性与充分性初步研究
本研究为单中心非随机开放标签交叉先导试验,纳入30例维持性血液透析的终末期肾病患者,比较常温常流量、高温常流量和高温低流量三种透析处方各1个月。主要结局显示高温低流量与常温常流量处方的充分透析比例无显著差异,提示在年轻且血流动力学稳定的患者中,提高透析液温度并降低流量可作为节水策略而不影响透析充分性与安全性。
要点
- 高温低流量处方与常温常流量处方的充分透析比例无显著差异。
- 将透析液流量从500 ml/min降至300 ml/min可减少40%的水消耗。
- 临床明显血流动力学不稳定仅发生在高温常流量处方的1次透析中。
核心结论
- 在年轻且血流动力学稳定的维持性血液透析患者中,提高透析液温度并降低透析液流量可在不损害透析充分性和安全性的前提下作为节水策略。
研究设计与样本
- 单中心非随机开放标签交叉先导试验,纳入30例维持性血液透析的终末期肾病患者,每种处方各使用1个月。
主要发现
- 共完成863次血液透析,每种处方287至288次。
- 主要结局充分透析(spKt/V≥1.2)比例在常温常流量处方为202次(70.14%),高温低流量处方为198次(68.75%),比值比1.07(95%CI 0.75至1.52,P=0.45)。
- 平均spKt/V和尿素下降率无显著差异。
- 临床明显血流动力学不稳定仅发生在高温常流量处方的1次透析中。
关键数值与推荐
- 充分透析定义为单室Kt/V(spKt/V)≥1.2。
- 透析液流量从500 ml/min降至300 ml/min可减少40%的水消耗。
临床怎么用
- 对于年轻且血流动力学稳定的维持性血液透析患者,可考虑采用高温低流量透析处方以节约用水。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Hemodialysis (HD) units require large quantities of water. To reduce water consumption without compromising the adequacy and safety of dialysis, we studied a novel HD prescription with high temperature and low flow dialysate. METHODS: This was a single-center nonrandomized open-label cross-over pilot trial in patients with end-stage kidney disease on maintenance HD. Each participant was subjected to 3 different dialysis prescriptions for 1 month each as follows: (i) normal temperature with normal flow dialysate (NTNF prescription), (ii) high temperature with normal flow dialysate (HTNF prescription), and (iii) high temperature with low flow dialysate (HTLF prescription). The primary outcome, assessed at the end of each dialysis session, was the delivery of "adequate" dialysis, as defined by a single-pool Kt/V (spKt/V) ≥1.2. Outcomes were evaluated by comparing the NTNF and HTLF prescriptions. RESULTS: A total of 863 sessions of HD were performed in 30 patients over 3 months, with 287 to 288 sessions in each of the 3 dialysis prescriptions. The primary outcome was not significantly different between the NTNF prescription (202 sessions [70.14%]) and the HTLF prescription (198 sessions [68.75%]) (odds ratio, 1.07; 95% confidence interval, 0.75 to 1.52; P = 0.45). The mean spKt/V and urea reduction ratio (URR) were not significantly different. Clinically evident hemodynamic instability occurred in only 1 dialysis session in the HTNF prescription. CONCLUSION: Increasing dialysate temperature while reducing dialysate flow rate (QD) can be used as a water conservation strategy without compromising the adequacy and safety of dialysis in young and hemodynamically stable patients. Reducing the QD from 500 ml/min to 300 ml/min reduces water consumption by 40%.
引用
- Solomon D, Arumugam V, Sakthirajan R, et al. A Pilot Study on the Safety and Adequacy of a Novel Ecofriendly Hemodialysis Prescription-Green Nephrology. Kidney Int Rep. 2024. PMID: 38707836. doi:10.1016/j.ekir.2024.02.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。