人工智能自动算法测量常染色体显性多囊肾病总肾脏体积
本研究开发并验证了一种基于集成U-net算法的人工智能工具,用于常规测量常染色体显性多囊肾病(ADPKD)患者的总肾脏体积(TKV)。在训练和内部交叉验证队列(227次1.5T MRI扫描)及独立临床验证队列(48次临床MRI扫描)中,算法与人工分割的median DICE评分为0.96,median TKV误差为-1.8%。该算法性能与人工分割相当,且手动修正时间显著缩短,适合临床应用。
要点
- AI算法测量TKV与人工分割高度一致,median DICE评分0.96。
- 临床验证中median TKV误差仅-1.8%,精度高。
- 算法输出手动修正时间8.5分钟,远低于人工分割的56分钟。
核心结论
- AI算法在ADPKD患者TKV测量中性能与人工分割相当,具有快速精准的特点,适合临床常规应用。
研究设计与样本
- 采用nnUNet方法构建集成U-net算法,训练和内部交叉验证队列为CYSTic联盟的227次1.5T MRI扫描(454个肾脏),由单一操作者手动分割。
- 独立临床验证队列为单中心48次连续临床MRI扫描,参考结果为6名分析员手动分割。
主要发现
- 训练或内部验证队列较临床验证队列年轻(平均年龄44.0 vs 51.5岁),女性与男性比例更高(1.2 vs 0.94)。
- CYSTic患者多数有PKD1突变(79%)和典型疾病(Mayo影像分类1类,86%)。
- 临床验证数据集中算法与人工分析员的median DICE评分左右肾均为0.96,median TKV误差为-1.8%。
- CYSTic数据集中手动分割肾脏耗时56(±28)分钟,而算法输出手动修正每次扫描耗时8.5(±9.2)分钟。
临床怎么用
- 该AI工具可用于临床常规测量ADPKD患者TKV,快速获得结果并仅需少量手动修正,有助于个体化预后评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Accurate tools to inform individual prognosis in patients with autosomal dominant polycystic kidney disease (ADPKD) are lacking. Here, we report an artificial intelligence (AI)-generated method for routinely measuring total kidney volume (TKV). METHODS: An ensemble U-net algorithm was created using the nnUNet approach. The training and internal cross-validation cohort consisted of all 1.5T magnetic resonance imaging (MRI) data acquired using 5 different MRI scanners (454 kidneys, 227 scans) in the CYSTic consortium, which was first manually segmented by a single human operator. As an independent validation cohort, we utilized 48 sequential clinical MRI scans with reference results of manual segmentation acquired by 6 individual analysts at a single center. The tool was then implemented for clinical use and its performance analyzed. RESULTS: The training or internal validation cohort was younger (mean age 44.0 vs. 51.5 years) and the female-to-male ratio higher (1.2 vs. 0.94) compared to the clinical validation cohort. The majority of CYSTic patients had PKD1 mutations (79%) and typical disease (Mayo Imaging class 1, 86%). The median DICE score on the clinical validation data set between the algorithm and human analysts was 0.96 for left and right kidneys with a median TKV error of -1.8%. The time taken to manually segment kidneys in the CYSTic data set was 56 (±28) minutes, whereas manual corrections of the algorithm output took 8.5 (±9.2) minutes per scan. CONCLUSION: Our AI-based algorithm demonstrates performance comparable to manual segmentation. Its rapidity and precision in real-world clinical cases demonstrate its suitability for clinical application.
引用
- Taylor J, Thomas R, Metherall P, et al. An Artificial Intelligence Generated Automated Algorithm to Measure Total Kidney Volume in ADPKD. Kidney Int Rep. 2023. PMID: 38344736. doi:10.1016/j.ekir.2023.10.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。